International Fire Inc
- Based in
- San Francisco
- On San Francisco permits
- Mar 2013 to May 2026
- Last 24 months
- 61 permits filed
461 permits since 2000: 283 completed, 86 in progress, 82 never finaled, 10 expired or cancelled.
Of the 82 never-finaled permits, 21 are 3 to 5 years old, 37 are 5 to 10 years old, 24 are over 10 years old.
This is the city’s permit record, not a license check. It does not show whether the state license is active, bonded or insured. How to read these records
Permits filed each year
How long permits take
Each point is the quarter the permits were filed, for all building permits across San Francisco. A median counts only permits that have finished, so the shaded recent quarters look faster than they will end up: their slow permits have not finished yet. Hover a point for the slowest 10%. Gaps mean fewer than 5 permits. A rise in the issue line is the city’s review backlog, not the contractor.
Most recent permits
Showing the 100 most recent of 461.
| Filed | Outcome | Address | Work described on the permit | Declared cost |
|---|---|---|---|---|
| May 13, 2026 | In progress issued May 2026 | 535 Arguello Bl | asbuilt to pa# 202402075384, added missing 2 smokes and pull, renamed floors to match elevator.Details
asbuilt to pa# 202402075384, added missing 2 smokes and pull, renamed floors to match elevator. | $500 |
| Feb 12, 2026 | In progress issued Feb 2026 | 555 Arguello Bl | upgrade (e) fire alarm system in non sprinkled building. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2025 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency sounders inDetails
upgrade (e) fire alarm system in non sprinkled building. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2025 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency sounders in | $24,730 |
| Feb 9, 2026 | In progress issued Mar 2026 | 1000 Franklin St | as built to pa 202504174599 relocate facu into garage, change 29 wired low frequency sounders to wireless. add shunt trip to elevator.Details
as built to pa 202504174599 relocate facu into garage, change 29 wired low frequency sounders to wireless. add shunt trip to elevator. | |
| Jan 14, 2026 | In progress issued Jan 2026 | 2299 Sacramento St | as-builts to pa #202507291807. per customer request low frequency sounders will be changed to wireless. fire panels will be relocated in basement.Details
as-builts to pa #202507291807. per customer request low frequency sounders will be changed to wireless. fire panels will be relocated in basement. | $17,000 |
| Jan 14, 2026 | In progress issued Jan 2026 | 311 Corbett Av | as builts for pa # 2025-0812-2802. add annunciatorDetails
as builts for pa # 2025-0812-2802. add annunciator | $1,000 |
| Jan 13, 2026 | In progress issued Jan 2026 | 1560 40th Av | ref pa #2019-1104-6328 & 2025-0417-4623: update plans to reflect locations of devices.Details
ref pa #2019-1104-6328 & 2025-0417-4623: update plans to reflect locations of devices. | |
| Jan 13, 2026 | In progress issued Jan 2026 | 1030 Jackson St | upgrade (e) fire alarm system in non sprinkled building to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull station in common areas and exits. install low frequency soundersDetails
upgrade (e) fire alarm system in non sprinkled building to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull station in common areas and exits. install low frequency sounders | $27,800 |
| Jan 13, 2026 | In progress issued Jan 2026 | 1765 Pacific Av | as builts to pa 202312062046 remove 3 smoke detectorsDetails
as builts to pa 202312062046 remove 3 smoke detectors | |
| Jan 13, 2026 | Completed final sign-off Jul 2026 | 3627 Cesar Chavez St | as builts to bpa: 202502200705 - change the system to wireless.Details
as builts to bpa: 202502200705 - change the system to wireless. | $3,780 |
| Jan 12, 2026 | Completed final sign-off May 2026 | 348 Church St | as built to pa 202308083961, 202508082643 change 3 horn strobes to wirelessDetails
as built to pa 202308083961, 202508082643 change 3 horn strobes to wireless | $300 |
| Jan 9, 2026 | In progress issued Jan 2026 | 661 Lombard St | as builts to p.a.#201602169650 due to panel malfunction initiating devices replaced with new at same location. new radio installedDetails
as builts to p.a.#201602169650 due to panel malfunction initiating devices replaced with new at same location. new radio installed | $5,000 |
| Oct 6, 2025 | In progress issued Oct 2025 | 4300 23rd St | upgrade (e) fire alarm system in partly sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 and nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobe, detectors, and pull stations in common area and exits. monitor sprinkler system.Details
upgrade (e) fire alarm system in partly sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 and nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobe, detectors, and pull stations in common area and exits. monitor sprinkler system. | $13,100 |
| Sep 12, 2025 | In progress issued Sep 2025 | 3028 Jackson St | as built pa 202507019973 to issue plans with clean corrective notesDetails
as built pa 202507019973 to issue plans with clean corrective notes | |
| Aug 26, 2025 | In progress issued Aug 2025 | 2235 Laguna St | wireless low frequency sounders will be wired. install facu with radio to monitor system.Details
wireless low frequency sounders will be wired. install facu with radio to monitor system. | $47,000 |
| Aug 21, 2025 | Completed final sign-off Apr 2026 | 235 19th Av | upgrade existing fire alarm system in non sprinkled building. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits.Details
upgrade existing fire alarm system in non sprinkled building. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. | $21,000 |
| Aug 21, 2025 | Completed final sign-off Oct 2025 | 2415 Van Ness Av | as-built to pa# 202310037911: changed alternate elevator recall from 2nd to g/fDetails
as-built to pa# 202310037911: changed alternate elevator recall from 2nd to g/f | |
| Aug 12, 2025 | In progress issued Aug 2025 | 311 Corbett Av | upgrade existing fire alarm system in non sprinklered building. comply with sffc sec 1103.7.61 and current cbc/cfc 2022 and nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency soundeDetails
upgrade existing fire alarm system in non sprinklered building. comply with sffc sec 1103.7.61 and current cbc/cfc 2022 and nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency sounde | $35,500 |
| Aug 8, 2025 | Completed final sign-off May 2026 | 348 Church St | as builts to pa # 2023-0808-3961. change system to addressable with wireless low frequency sounders.Details
as builts to pa # 2023-0808-3961. change system to addressable with wireless low frequency sounders. | $9,400 |
| Aug 8, 2025 | Completed final sign-off Feb 2026 | 71 Water St | as builts for pa # 2021-0126-3375. new adu need to add three low frequency sounders. ref pa #2018-0110-8309 (new adu) # 2021-0621-2852 (asb-1)Details
as builts for pa # 2021-0126-3375. new adu need to add three low frequency sounders. ref pa #2018-0110-8309 (new adu) # 2021-0621-2852 (asb-1) | $5,500 |
| Jul 29, 2025 | Completed final sign-off Mar 2026 | 248 Guerrero St | to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 * nfpa 72 2022 code requirement. install new facu with radio to monitor system. horn/storbes, detectors and pull stations in common areas and exits. install low frequency sounders inside sleeping rooms. to comply with fire alarm system inDetails
to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 * nfpa 72 2022 code requirement. install new facu with radio to monitor system. horn/storbes, detectors and pull stations in common areas and exits. install low frequency sounders inside sleeping rooms. to comply with fire alarm system in | $19,800 |
| Jul 29, 2025 | In progress issued Jul 2025 | 2299 Sacramento St | to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 * nfpa 72 2022 code requirement. install new facu with radio to monitor system. horn/storbes, detectors and pull stations in common areas and exits. install low frequency sounders inside sleeping rooms.Details
to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 * nfpa 72 2022 code requirement. install new facu with radio to monitor system. horn/storbes, detectors and pull stations in common areas and exits. install low frequency sounders inside sleeping rooms. | $45,700 |
| Jul 28, 2025 | In progress issued Jul 2025 | 1012 Cole St | as builts to 202307031403. change conventiional to addressable and smoke to heat above facuDetails
as builts to 202307031403. change conventiional to addressable and smoke to heat above facu | |
| Jul 28, 2025 | Completed final sign-off Feb 2026 | 1200 Indiana St | install new fire alarm system in fully sprinkled bldg. install new facu w/ sprinkler monitoring system. install horn/strobes in common areas and a detector and pull station at facu.Details
install new fire alarm system in fully sprinkled bldg. install new facu w/ sprinkler monitoring system. install horn/strobes in common areas and a detector and pull station at facu. | $14,400 |
| Jul 7, 2025 | Completed final sign-off Feb 2026 | 704 Bush St | as builts to pa #202505025674. add module to monitor kitchen hood systemDetails
as builts to pa #202505025674. add module to monitor kitchen hood system | $2,500 |
| Jul 7, 2025 | Completed final sign-off Jul 2026 | 3562 17th St | upgrade (e) fire alarm system in partly sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 and nfpa 72 2022 code requirements. intall new facu with radio to monitor system. hom/strobes, detectors and pull stations in common areas and exits. install low frequency soundersDetails
upgrade (e) fire alarm system in partly sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 and nfpa 72 2022 code requirements. intall new facu with radio to monitor system. hom/strobes, detectors and pull stations in common areas and exits. install low frequency sounders | $17,700 |
| Jul 1, 2025 | In progress issued Jul 2025 | 3028 Jackson St | upgrade (e) fire alarm system in partly sprinklered bldg. to comply with sffc sec 1103.7.61 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency soundersDetails
upgrade (e) fire alarm system in partly sprinklered bldg. to comply with sffc sec 1103.7.61 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency sounders | $20,500 |
| Jun 30, 2025 | In progress issued Jun 2025 | 689 14th St | upgrade (e) fire alarm system in non sprinklered building. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency soundersDetails
upgrade (e) fire alarm system in non sprinklered building. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency sounders | $14,400 |
| Jun 30, 2025 | In progress issued Jul 2025 | 1936 15th St | as builtss to 202406184725. change radio modelDetails
as builtss to 202406184725. change radio model | |
| Jun 30, 2025 | Completed final sign-off Mar 2026 | 1930 15th St | as builts to 202406184724. change radio modelDetails
as builts to 202406184724. change radio model | |
| Jun 30, 2025 | Completed final sign-off Aug 2025 | 2200 Beach St | as-builts to pa# 202501279092. changed lobby horn/strobe to wireless, changed two 1st floor smokes to heat, deleted pulls from 1st, 2nd, 3rd floors added smoke to 4th floor.Details
as-builts to pa# 202501279092. changed lobby horn/strobe to wireless, changed two 1st floor smokes to heat, deleted pulls from 1st, 2nd, 3rd floors added smoke to 4th floor. | |
| Jun 9, 2025 | Completed final sign-off Sep 2025 | 155 Connecticut St | install new voice communication system in non sprinled bldg. ref pa# 202412187086. to comply with nfpa 72 code requirements. install new facu/evac with radio to monitor sysem. speaker/strobes, detectors and pull stations in common areas and exits.Details
install new voice communication system in non sprinled bldg. ref pa# 202412187086. to comply with nfpa 72 code requirements. install new facu/evac with radio to monitor sysem. speaker/strobes, detectors and pull stations in common areas and exits. | $21,700 |
| Jun 9, 2025 | In progress issued Jun 2025 | 654 08th Av | upgrade (e) fire alarm system to non sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exists. install low frequency sounders inDetails
upgrade (e) fire alarm system to non sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exists. install low frequency sounders in | $22,500 |
| Jun 3, 2025 | Completed final sign-off Oct 2025 | 655 Corbett Av | as built to pa 202504104174 renamed floors and stairs; added annunciator moduleDetails
as built to pa 202504104174 renamed floors and stairs; added annunciator module | $500 |
| May 30, 2025 | Completed final sign-off Jan 2026 | 291 Santos St | upgrade existing fire alarm system in non sprinklered building. to comply with sffc sec. 1103.7.6.1 & current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas & exits. install low frequencyDetails
upgrade existing fire alarm system in non sprinklered building. to comply with sffc sec. 1103.7.6.1 & current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas & exits. install low frequency | $32,000 |
| May 8, 2025 | Completed final sign-off Jun 2025 | 1317 Hyde St | as-built fire alarm to pa 202312142517. change radio revised device points.Details
as-built fire alarm to pa 202312142517. change radio revised device points. | |
| May 8, 2025 | Completed final sign-off Aug 2025 | 1145 Hayes St | as-built fire alarm to pa 202411084642. add one low freq horn to unit 14.Details
as-built fire alarm to pa 202411084642. add one low freq horn to unit 14. | |
| May 2, 2025 | In progress issued May 2025 | 615 Cole St | upgrade (e) fire alarm system in non sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency soundersDetails
upgrade (e) fire alarm system in non sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. install low frequency sounders | $36,000 |
| May 2, 2025 | Completed final sign-off Jun 2025 | 1040 Greenwich St | as-built to permit 202502271234. added smoke detector to top of stairs 3rd and 4th floors. rename floors to reflect job site.Details
as-built to permit 202502271234. added smoke detector to top of stairs 3rd and 4th floors. rename floors to reflect job site. | |
| May 2, 2025 | Completed final sign-off Feb 2026 | 704 Bush St | upgrade e fire alarm system in partly sprinklered building. to comply with sffc sec.1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2022 code req. install new facu w radio to monitor system. horn strobes, detectors, pull stations in common areas and exits. low freq souders inside sleeping roomsDetails
upgrade e fire alarm system in partly sprinklered building. to comply with sffc sec.1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2022 code req. install new facu w radio to monitor system. horn strobes, detectors, pull stations in common areas and exits. low freq souders inside sleeping rooms | $57,800 |
| Apr 25, 2025 | In progress issued May 2025 | 1061 Clay St | to comply w/ sffc sec 1103.7.6.1. & current cbc/cfc 2025 & nfpa 72 2022. upgrade fire alarm system in non-sprinklered building. install new facu w/ radio to monitor system, detectors & pull stations in common area & exits. install low frequency sounders inside sleeping areaDetails
to comply w/ sffc sec 1103.7.6.1. & current cbc/cfc 2025 & nfpa 72 2022. upgrade fire alarm system in non-sprinklered building. install new facu w/ radio to monitor system, detectors & pull stations in common area & exits. install low frequency sounders inside sleeping area | $24,100 |
| Apr 25, 2025 | In progress issued Jun 2025 | 1000 Franklin St | upgrade (e) fire alarm system in partyl sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits.Details
upgrade (e) fire alarm system in partyl sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits. | $67,400 |
| Apr 17, 2025 | In progress issued May 2025 | 1560 40th Av | ref permit 201911046328. repair like for like (e) f/a system in sprinkled building. relocate (e) facu and radio to main building from pre school. replace (e) pulls, horns and bells with new in same locations in main building.Details
ref permit 201911046328. repair like for like (e) f/a system in sprinkled building. relocate (e) facu and radio to main building from pre school. replace (e) pulls, horns and bells with new in same locations in main building. | $12,000 |
| Apr 10, 2025 | Completed final sign-off Oct 2025 | 655 Corbett Av | upgrade (e) fire alarm system in partly sprinkled building. to comply with sffc sec. 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors, and pull stations in common areas and exits. install module to monitorDetails
upgrade (e) fire alarm system in partly sprinkled building. to comply with sffc sec. 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors, and pull stations in common areas and exits. install module to monitor | $70,500 |
| Mar 21, 2025 | Completed final sign-off Oct 2025 | 967 Haight St | upgrade (e) fire alarm system in party sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72.2022 code requirements. install new facu with radio to monitor system. hor/strobes, detectors and pull stations in common area and exits. install low frequency sounders insideDetails
upgrade (e) fire alarm system in party sprinkled bldg. to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72.2022 code requirements. install new facu with radio to monitor system. hor/strobes, detectors and pull stations in common area and exits. install low frequency sounders inside | $18,700 |
| Mar 20, 2025 | Completed final sign-off Jul 2026 | 172 Beaumont Av | install facu, radio to monitor, smoke and pull near facu the system will monitor sprinkler system waterflow and supervisory ref 201610140341 & 201810042226Details
install facu, radio to monitor, smoke and pull near facu the system will monitor sprinkler system waterflow and supervisory ref 201610140341 & 201810042226 | $8,500 |
| Feb 27, 2025 | In progress issued Mar 2025 | 2164 Hyde St | ref pa 202311150837 update elevator and notification informationDetails
ref pa 202311150837 update elevator and notification information | $100 |
| Feb 27, 2025 | Completed final sign-off May 2025 | 1040 Greenwich St | upgrade (e) fire alarm system in non sprinklered bldg (elevator lobby); to comply with sffc sec cbccfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits and low frequency sounders inside sleepingDetails
upgrade (e) fire alarm system in non sprinklered bldg (elevator lobby); to comply with sffc sec cbccfc 2022 & nfpa 72 2022 code requirements. install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits and low frequency sounders inside sleeping | $34,700 |
| Feb 20, 2025 | Completed final sign-off May 2026 | 777 Rhode Island St | upgrade (e) fire alarm system in non-sprinklered building; comply with sffc sec 1103.7.6.1 and currect cbc/cfc 2022 & nfpa 72 2022 code requirements; install new facu with radio to monitor system. horn/strobes, detectors, and pull stations in common areas and exits and low frequency sounders insideDetails
upgrade (e) fire alarm system in non-sprinklered building; comply with sffc sec 1103.7.6.1 and currect cbc/cfc 2022 & nfpa 72 2022 code requirements; install new facu with radio to monitor system. horn/strobes, detectors, and pull stations in common areas and exits and low frequency sounders inside | $14,700 |
| Feb 20, 2025 | In progress issued Feb 2025 | 429 28th St | upgrade (e) fire alarm system in party sprinkled building (lobby only). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2025 code requirements; install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits and low frequencyDetails
upgrade (e) fire alarm system in party sprinkled building (lobby only). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2025 code requirements; install new facu with radio to monitor system. horn/strobes, detectors and pull stations in common areas and exits and low frequency | $17,600 |
| Feb 20, 2025 | Completed final sign-off Jul 2026 | 3627 Cesar Chavez St | upgrade (e) fire alram system in partly sprinklered bldg. to comply with sffc 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2025 code requirements. install new facu w/radio to monitor system. horn/strobes, detectors and pull stations in commmon areas and exits. install module to monitor flow switchDetails
upgrade (e) fire alram system in partly sprinklered bldg. to comply with sffc 1103.7.6.1 and current cbc/cfc 2025 & nfpa 72 2025 code requirements. install new facu w/radio to monitor system. horn/strobes, detectors and pull stations in commmon areas and exits. install module to monitor flow switch | $16,300 |
| Jan 27, 2025 | Completed final sign-off Jul 2025 | 2200 Beach St | upgrade existing fire alarm system in-partly sprinkled bldg(elevator lobby).to comply with sffc sec.1103.7.6.1 & nfpa 70 2025 code requirements.install new facu w/ radio to monitor system.horn/strobes, detectors & pull stations in common areas&exits.install module to monitor flow switch & sleep rmsDetails
upgrade existing fire alarm system in-partly sprinkled bldg(elevator lobby).to comply with sffc sec.1103.7.6.1 & nfpa 70 2025 code requirements.install new facu w/ radio to monitor system.horn/strobes, detectors & pull stations in common areas&exits.install module to monitor flow switch & sleep rms | $18,200 |
| Jan 6, 2025 | In progress issued Jan 2025 | 130 Gardenside Dr | upgrade existing fire alarm system in party sprinkled bldg (storage area level 2 no existing flow switch). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2025 code requirements. install new facu radio to monitor system. horn/strobes, detectors and pull stations in common...Details
upgrade existing fire alarm system in party sprinkled bldg (storage area level 2 no existing flow switch). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2025 code requirements. install new facu radio to monitor system. horn/strobes, detectors and pull stations in common... | $35,000 |
| Jan 6, 2025 | In progress issued Jan 2025 | 140 Gardenside Dr | upgrade existing fire alarm system in party sprinkled bldg (storage area level 2 no existing flow switch). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2025 code requirements. install new facu radio to monitor system. horn/strobes, detectors and pull stations in common...Details
upgrade existing fire alarm system in party sprinkled bldg (storage area level 2 no existing flow switch). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2025 code requirements. install new facu radio to monitor system. horn/strobes, detectors and pull stations in common... | $35,000 |
| Jan 6, 2025 | In progress issued Jan 2025 | 110 Gardenside Dr | upgrade existing fire alarm system in party sprinkled bldg (storage area level 2 no existing flow switch). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2025 code requirements. install new facu radio to monitor system. horn/strobes, detectors and pull stations in common...Details
upgrade existing fire alarm system in party sprinkled bldg (storage area level 2 no existing flow switch). to comply with sffc sec 1103.7.6.1 and current cbc/cfc 2025 and nfpa 72 2025 code requirements. install new facu radio to monitor system. horn/strobes, detectors and pull stations in common... | $35,000 |
| Nov 15, 2024 | In progress issued Nov 2024 | 2205 Sacramento St | upgrade existing fire alarm ystem in sprinkled bldg to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to monitor system. detector and pull station at facu horn/strobes in common areas. install low frequency sounders inside sleeping rooms.Details
upgrade existing fire alarm ystem in sprinkled bldg to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to monitor system. detector and pull station at facu horn/strobes in common areas. install low frequency sounders inside sleeping rooms. | $27,000 |
| Nov 8, 2024 | Completed final sign-off Aug 2025 | 1145 Hayes St | upgrade (e) fire alarm system in non sprinklered building to comply with 2022 cbc,cfc, nfpa 72 and sffc sec 1103.7.6.1; install new facu with radio to monitor system. horn/strobes. detectors and pull stations in common areas and exits. install low frequency sounders inside sleeping roomsDetails
upgrade (e) fire alarm system in non sprinklered building to comply with 2022 cbc,cfc, nfpa 72 and sffc sec 1103.7.6.1; install new facu with radio to monitor system. horn/strobes. detectors and pull stations in common areas and exits. install low frequency sounders inside sleeping rooms | $39,000 |
| Nov 5, 2024 | In progress issued Nov 2024 | 1400 Washington St | as built pa 202312062047 due to changes in units add 9 additional low wireless frequency soundersDetails
as built pa 202312062047 due to changes in units add 9 additional low wireless frequency sounders | $5,250 |
| Nov 5, 2024 | In progress issued Aug 2025 | 879 Dolores St | upgrade (e) fire alarm system in sprinkled bldg to comply with 2022cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to monitor system. horn/strobes in commom areas and a detector and pull station at facu. install wireless low frequency sounders inside sleeping rooms.Details
upgrade (e) fire alarm system in sprinkled bldg to comply with 2022cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to monitor system. horn/strobes in commom areas and a detector and pull station at facu. install wireless low frequency sounders inside sleeping rooms. | $10,600 |
| Nov 5, 2024 | In progress issued Feb 2025 | 1535 48th Av | upgrade existing fire alarm system in non-sprinklered building to comply with 2022 cbc,cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to minotor system. horn/stroves, detectors and pull station in common areas and exits. install low frequency sounders inside sleeping roomsDetails
upgrade existing fire alarm system in non-sprinklered building to comply with 2022 cbc,cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to minotor system. horn/stroves, detectors and pull station in common areas and exits. install low frequency sounders inside sleeping rooms | $28,800 |
| Oct 24, 2024 | In progress issued Oct 2024 | 415 Jones St | upgrade existing fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. existing facu, smokes, horn strobes and pulls will stay. add power supply, an annunciator at front and radio to monitor system.install low frequency sounders inside sleeping rmsDetails
upgrade existing fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. existing facu, smokes, horn strobes and pulls will stay. add power supply, an annunciator at front and radio to monitor system.install low frequency sounders inside sleeping rms | $18,000 |
| Oct 11, 2024 | In progress issued Oct 2024 | 3371 16th St | like for like fire system replacement due to panel failure in non sprinkled building. replace existing smokes, pulls and notification devices in same placesDetails
like for like fire system replacement due to panel failure in non sprinkled building. replace existing smokes, pulls and notification devices in same places | $15,000 |
| Sep 13, 2024 | Completed final sign-off Jan 2026 | 2973 Folsom St | upgrade fire alar system in non sprinklered building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replac e facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low freq sounders inside sleeping roomsDetails
upgrade fire alar system in non sprinklered building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replac e facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low freq sounders inside sleeping rooms | $34,300 |
| Sep 13, 2024 | In progress issued Sep 2024 | 190 21st Av | upgrade existing fire alarm system in non sprinklered building toi comply with 2022 cbc/cfc, nfpa 72 and sffcsec 1103.7.6.1. replace e facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in comomon areas and install low frequency sounders insideDetails
upgrade existing fire alarm system in non sprinklered building toi comply with 2022 cbc/cfc, nfpa 72 and sffcsec 1103.7.6.1. replace e facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in comomon areas and install low frequency sounders inside | $17,800 |
| Aug 29, 2024 | Completed final sign-off Jul 2025 | 2265 Mission St | upgrade (e) fire alarm system in partly sprinkled building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in comon areas and pulls each level and exit horn/strobes in common areas and install low freq sounder inside sleeping roomsDetails
upgrade (e) fire alarm system in partly sprinkled building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in comon areas and pulls each level and exit horn/strobes in common areas and install low freq sounder inside sleeping rooms | $26,000 |
| Aug 29, 2024 | Completed final sign-off Jul 2026 | 570 Page St | upgrade (e) fire alarm system in partly sprinkled building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in comon areas and pulls each level and exit horn/strobes in common areas and install low freq sounder inside sleeping roomsDetails
upgrade (e) fire alarm system in partly sprinkled building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in comon areas and pulls each level and exit horn/strobes in common areas and install low freq sounder inside sleeping rooms | $21,800 |
| Aug 29, 2024 | Completed final sign-off Jun 2025 | 2202 California St | upgrade (e) fire alarm system in partly sprinkled building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in comon areas and pulls each level and exit horn/strobes in common areas and install low freq sounder inside sleeping roomsDetails
upgrade (e) fire alarm system in partly sprinkled building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in comon areas and pulls each level and exit horn/strobes in common areas and install low freq sounder inside sleeping rooms | $19,700 |
| Aug 22, 2024 | In progress issued Aug 2024 | 2941 Gough St | upgrade existing fire alarm system in partly sprinkled bldg to comply with 2022 cbc/cfc. nfpa 72 and sffc sec 1103.7.6.1. replace existing facu and add radio to monitor system. smokes in common areas and pull each level and exit. horn/strobe in common areas and install low frequncy sounders insideDetails
upgrade existing fire alarm system in partly sprinkled bldg to comply with 2022 cbc/cfc. nfpa 72 and sffc sec 1103.7.6.1. replace existing facu and add radio to monitor system. smokes in common areas and pull each level and exit. horn/strobe in common areas and install low frequncy sounders inside | $17,300 |
| Aug 16, 2024 | Completed final sign-off Aug 2026 | 3655 Vicente St | upgrade existing fire alarm in non sprinklered bldg to comply with sffc 1103.7.6.1 & nfpa 72. replace existing facu & add radio to monitor system. smokes in common areas and pull each level & exit. horn/strobes in common areas and install low frequency sounders inside sleeping roomsDetails
upgrade existing fire alarm in non sprinklered bldg to comply with sffc 1103.7.6.1 & nfpa 72. replace existing facu & add radio to monitor system. smokes in common areas and pull each level & exit. horn/strobes in common areas and install low frequency sounders inside sleeping rooms | $21,000 |
| Aug 8, 2024 | Completed final sign-off Sep 2025 | 425 Hyde St | upgrade (e) fire alarm system in non-sprinkled building to comply with 2022 cbc/cfc,nfpa 72 and sffc 1103.7.6.1.keep (e) facu and add radio to monitor system. smokes in common areas and pulls each level/exit. horn/strobes in common areas and install low freq sounders inside sleeping room.sDetails
upgrade (e) fire alarm system in non-sprinkled building to comply with 2022 cbc/cfc,nfpa 72 and sffc 1103.7.6.1.keep (e) facu and add radio to monitor system. smokes in common areas and pulls each level/exit. horn/strobes in common areas and install low freq sounders inside sleeping room.s | $35,500 |
| Aug 8, 2024 | In progress issued Aug 2024 | 2645 Sacramento St | upgrade (e) fire alarm system in non-sprinkled building to comply with 2022 cbc/cfc,nfpa 72 and sffc 1103.7.6.1.keep (e) facu and add radio to monitor system. smokes in common areas and pulls each level/exit. horn/strobes in common areas and install low freq sounders inside sleeping room.sDetails
upgrade (e) fire alarm system in non-sprinkled building to comply with 2022 cbc/cfc,nfpa 72 and sffc 1103.7.6.1.keep (e) facu and add radio to monitor system. smokes in common areas and pulls each level/exit. horn/strobes in common areas and install low freq sounders inside sleeping room.s | $28,700 |
| Jul 25, 2024 | In progress issued Jul 2024 | 450 Jones St | as-builts to pa# 202311221330. due to elevator modernization 8 new smoke detectors and 3 new relay modules will be installed.Details
as-builts to pa# 202311221330. due to elevator modernization 8 new smoke detectors and 3 new relay modules will be installed. | $10,000 |
| Jul 25, 2024 | Completed final sign-off Sep 2024 | 1700 Mcallister St | added 12 new low frequency horns to achieve 75db at the pillow. as builts to pa# 202011108662Details
added 12 new low frequency horns to achieve 75db at the pillow. as builts to pa# 202011108662 | $5,600 |
| Jul 24, 2024 | In progress issued Jul 2024 | 485 Warren Dr | upgrade (e) fire alarm system in non sprinklered building to comply w/ 2022 cbc/nfpa72 and sffc sec 1103.7.6.1, replace (e) facu and add radio to monitor system, smokes in common areas and pulls each level and exit. horn strobes in common areas and install low frequency sounders inside sleeping roomDetails
upgrade (e) fire alarm system in non sprinklered building to comply w/ 2022 cbc/nfpa72 and sffc sec 1103.7.6.1, replace (e) facu and add radio to monitor system, smokes in common areas and pulls each level and exit. horn strobes in common areas and install low frequency sounders inside sleeping room | $18,000 |
| Jul 24, 2024 | In progress issued Jul 2025 | 1580 Golden Gate Av | fire only- fire alarm upgrade in non sprikled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. horn strobes in common areas and install low freq. sounder inside sleeping roomsDetails
fire only- fire alarm upgrade in non sprikled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. horn strobes in common areas and install low freq. sounder inside sleeping rooms | $13,000 |
| Jul 24, 2024 | In progress issued Mar 2025 | 1000 Great Hy | install 5 new duct detectors with relay modules to be tied into existing facu. ref permit 202111243134Details
install 5 new duct detectors with relay modules to be tied into existing facu. ref permit 202111243134 | $11,000 |
| Jul 12, 2024 | In progress filed Jul 2024, not yet issued | 1151 Scott St | to verify existing sound levels in sleeping areas. complying with sffc section 1103.7.6.1Details
to verify existing sound levels in sleeping areas. complying with sffc section 1103.7.6.1 | |
| Jul 12, 2024 | In progress filed Jul 2024, not yet issued | 1150 Scott St | to verify existing sound levels in sleeping areas. complying with sffc section 1103.7.6.1Details
to verify existing sound levels in sleeping areas. complying with sffc section 1103.7.6.1 | |
| Jul 12, 2024 | Completed final sign-off Sep 2024 | 1795 38th Av | as-built to permit 202307132083. added waterflow device and sprinkler bell on g/f to reflect job site.Details
as-built to permit 202307132083. added waterflow device and sprinkler bell on g/f to reflect job site. | $100 |
| Jul 5, 2024 | In progress issued Jul 2025 | 2311 Cabrillo St | upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleepinDetails
upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleepin | $18,900 |
| Jul 5, 2024 | In progress issued Apr 2025 | 428 Burnett Av | upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1 replace (e) facu and add radio to monitor system. smokes in common areaas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleepinDetails
upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1 replace (e) facu and add radio to monitor system. smokes in common areaas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleepin | $24,500 |
| Jul 5, 2024 | In progress issued Jul 2024 | 1 Florence St | upgrade (e) fire alarm system in non sprinkled bldg to comply with 2022 cbc/cfc, nfpa 72 and sffc section 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install lf sounders inside sleeping rooms.Details
upgrade (e) fire alarm system in non sprinkled bldg to comply with 2022 cbc/cfc, nfpa 72 and sffc section 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install lf sounders inside sleeping rooms. | $25,700 |
| Jul 2, 2024 | Completed final sign-off May 2025 | 2379 20th Av | upgrade existing fire alarm system in non sprinkled bldg to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace existing facu and add radio to monitor system. smokes in common area and pulls each level and exit. horn/strobe in common area and install low frequency sounders insideDetails
upgrade existing fire alarm system in non sprinkled bldg to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace existing facu and add radio to monitor system. smokes in common area and pulls each level and exit. horn/strobe in common area and install low frequency sounders inside | $16,600 |
| Jul 2, 2024 | Completed final sign-off Mar 2026 | 326 12th Av | upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rmDetails
upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rm | $20,700 |
| Jun 18, 2024 | Completed final sign-off Mar 2026 | 1936 15th St | upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rmDetails
upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rm | $17,300 |
| Jun 18, 2024 | Completed final sign-off Mar 2026 | 1930 15th St | upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rmDetails
upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rm | $17,300 |
| Jun 14, 2024 | Completed final sign-off Aug 2024 | 35 Buena Vista Tr | reduce a currupted 2-inch galvanized pipe with a new copper type k pipe it is a 2 inch dedicated fire undergroundDetails
reduce a currupted 2-inch galvanized pipe with a new copper type k pipe it is a 2 inch dedicated fire underground | $5,000 |
| Jun 11, 2024 | In progress issued Jun 2024 | 615 Taylor St | to verify (e) sound levels in sleeping area, complying with sffc section 1103.7.6.1Details
to verify (e) sound levels in sleeping area, complying with sffc section 1103.7.6.1 | |
| Jun 4, 2024 | Completed final sign-off Feb 2025 | 1451 Larkin St | upgrade (e) fire alarm system in partly sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas and pulls peach level and exit. horn/strobes in common areas and install low freq sounders inside sleepingDetails
upgrade (e) fire alarm system in partly sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common areas and pulls peach level and exit. horn/strobes in common areas and install low freq sounders inside sleeping | $20,700 |
| May 24, 2024 | In progress filed May 2024, not yet issued | 347 Eddy St | upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec. 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common area and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleepinDetails
upgrade (e) fire alarm system in non sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec. 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common area and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleepin | $64,000 |
| May 24, 2024 | In progress issued May 2024 | 1845 Cabrillo St | upgrade (e) fire alarm system in non sprinkled building to comply w/ 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common area and pulls each level and exit. horn/strobes in common area and install low frequency sounders inside sleeping rmDetails
upgrade (e) fire alarm system in non sprinkled building to comply w/ 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system. smokes in common area and pulls each level and exit. horn/strobes in common area and install low frequency sounders inside sleeping rm | $19,900 |
| May 24, 2024 | In progress filed May 2024, not yet issued | 954 Geary St | upgrade (e) fire alarm system in non sprinkled building to comply w/ 2022 cbc/cfc, nfpa 72 and sffc sec. 1103.7.6.1. replace (e) facu and add radio monitor system. smokes in common area and pulls each level and exit. horn/strobes in common areas and install low freq sounders inside sleeping rooms.Details
upgrade (e) fire alarm system in non sprinkled building to comply w/ 2022 cbc/cfc, nfpa 72 and sffc sec. 1103.7.6.1. replace (e) facu and add radio monitor system. smokes in common area and pulls each level and exit. horn/strobes in common areas and install low freq sounders inside sleeping rooms. | $41,440 |
| May 24, 2024 | In progress issued May 2024 | 506 Grove St | upgrade (e) fire alarm system in partly sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system . smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low freq. sounders inside roomsDetails
upgrade (e) fire alarm system in partly sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. replace (e) facu and add radio to monitor system . smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low freq. sounders inside rooms | $25,000 |
| May 21, 2024 | Completed final sign-off Apr 2026 | 1251 Turk St | international fire inc. will replace like for like devices of the (e) fire alarm system with new devices to allow proper operation.Details
international fire inc. will replace like for like devices of the (e) fire alarm system with new devices to allow proper operation. | $131,000 |
| May 20, 2024 | Completed final sign-off Jan 2025 | 69 Henry St | upgrade (e) fire alarm system in non-sprinklered building to comply with 2022cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1; replace (e) facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders insideDetails
upgrade (e) fire alarm system in non-sprinklered building to comply with 2022cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1; replace (e) facu and add radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside | $19,000 |
| May 20, 2024 | Completed final sign-off Dec 2025 | 313 02nd Av | ref pa 202104078116 upgrade (e) fire alarm system with pulls @ every exit and replace bells with horn/strobesDetails
ref pa 202104078116 upgrade (e) fire alarm system with pulls @ every exit and replace bells with horn/strobes | $3,000 |
| May 13, 2024 | In progress filed May 2024, not yet issued | 381 Turk St | upgrade e) fire alarm system in non sprinkled bldg to comply w/ 2022 cbc/cfc nfpa 72 & sffc sec 1103.7.6.1. replace e faca & add radio to monitor system in common areas & pulls each lvl & exit. horn/strobes in common area & install low fre sounders in sleeping areasDetails
upgrade e) fire alarm system in non sprinkled bldg to comply w/ 2022 cbc/cfc nfpa 72 & sffc sec 1103.7.6.1. replace e faca & add radio to monitor system in common areas & pulls each lvl & exit. horn/strobes in common area & install low fre sounders in sleeping areas | $52,700 |
| Apr 23, 2024 | Expired or cancelled cancelled Jun 2026 | 839 Leavenworth St | upgrade e) fire alarm system in sprinkled bldg to compy w/ 2022 cbc/cfc, napa 72 & sffd 1103.7.6.1. install n) fava w/ radio to monitor system, smokes in common area for elevator revall & pull at facu. horn/strobe in common areas & install low freq sounders in sleeping roomsDetails
upgrade e) fire alarm system in sprinkled bldg to compy w/ 2022 cbc/cfc, napa 72 & sffd 1103.7.6.1. install n) fava w/ radio to monitor system, smokes in common area for elevator revall & pull at facu. horn/strobe in common areas & install low freq sounders in sleeping rooms | $77,300 |
| Apr 23, 2024 | In progress issued May 2024 | 109 Buchanan St | upgrade (e) fire alarm system in partly sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in commom areas and install low frequency sounders include sleepiDetails
upgrade (e) fire alarm system in partly sprinkled building to comply with 2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. install new facu with radio to monitor system. smokes in common areas and pulls each level and exit. horn/strobes in commom areas and install low frequency sounders include sleepi | $20,300 |
| Apr 23, 2024 | In progress issued Feb 2026 | 430 Arguello Bl | upgrade (e) fire alarm system in non sprinkled building to comply w/2022 nfpa 72 and sffc sec 1103.6.7.1. install (n) facu w/radio to monitor system . smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rooms.Details
upgrade (e) fire alarm system in non sprinkled building to comply w/2022 nfpa 72 and sffc sec 1103.6.7.1. install (n) facu w/radio to monitor system . smokes in common areas and pulls each level and exit. horn/strobes in common areas and install low frequency sounders inside sleeping rooms. | $23,500 |
| Apr 9, 2024 | Completed final sign-off Mar 2025 | 530 Bartlett St | upgrade existing fire alarm system in non sprinklered building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. existing facu with existing radio to monitor system. smokes in common areas and pulls each level and exit; horn/strobes in common areas and install low frequency sounders insideDetails
upgrade existing fire alarm system in non sprinklered building to comply w/2022 cbc/cfc, nfpa 72 and sffc sec 1103.7.6.1. existing facu with existing radio to monitor system. smokes in common areas and pulls each level and exit; horn/strobes in common areas and install low frequency sounders inside | $8,000 |