Block 3956, lot 003
1830 17th St
- City’s use
- Industrial
- Built
- 1949
- Stories
- 2
- Rooms
- 1 bathroom
- Building
- 7,275 sq ft
- Lot
- 5,898 sq ft
- Zoning
- M2
- Construction type
- D
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
12 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Aug 19, 2019 | Never finaled issued Aug 2019, no final | 1830 17th St | street spaceDetails
street space | ||
| Aug 1, 2019 | Completed final sign-off Oct 2020 | 1830 17th St | Aquamatic Fire Protection | revised the lower level fire sprinkler design from previously approved submittal appln #201904036951Details
revised the lower level fire sprinkler design from previously approved submittal appln #201904036951 | |
| Jun 19, 2019 | Completed final sign-off Mar 2020 | 1830 17th St | A V F Systems Inc | install fire alarm system with occupant notification. ref pa 2018-0920-0887Details
install fire alarm system with occupant notification. ref pa 2018-0920-0887 | $12,000 |
| Jun 7, 2019 | Never finaled issued Jun 2019, no final | 1830 17th St | street space onlyDetails
street space only | ||
| Apr 10, 2019 | Never finaled issued Apr 2019, no final | 1830 17th St | street spaceDetails
street space | ||
| Apr 3, 2019 | Never finaled issued Jun 2019, no final | 1830 17th St | Aquamatic Fire Protection | install new overhead sprinkler system. begin @ (e) underground. modify existing. stubbed into riser room. install new back flow preventer. reconnect the wall mounted fdc. install new riser control assembly supplying new overhead wet pipe fire sprinkler system for 2 story building. 99 heads.Details
install new overhead sprinkler system. begin @ (e) underground. modify existing. stubbed into riser room. install new back flow preventer. reconnect the wall mounted fdc. install new riser control assembly supplying new overhead wet pipe fire sprinkler system for 2 story building. 99 heads. | $59,900 |
| Feb 14, 2019 | Never finaled issued Feb 2019, no final | 1830 17th St | street spaceDetails
street space | ||
| Feb 14, 2019 | Completed final sign-off Feb 2021 | 1830 17th St | Oliver & Company Inc. | temporary shoring of roof & walls to assure safety and stability during demolition and full roof replacement. work will be done concurrently with bpa #201809200887.Details
temporary shoring of roof & walls to assure safety and stability during demolition and full roof replacement. work will be done concurrently with bpa #201809200887. | $25,000 |
| Sep 20, 2018 | Completed final sign-off Feb 2021 | 1830 17th St | Oliver & Company Inc. | remodel of (e) 2 story building. no change of use. no historic re source. partial roof collapse & notice of violation #201845721 & correction notice require full roof replacement. update interior spaces & accessibility upgrade and include.Details
remodel of (e) 2 story building. no change of use. no historic re source. partial roof collapse & notice of violation #201845721 & correction notice require full roof replacement. update interior spaces & accessibility upgrade and include. | $1,000,000 |
| May 22, 2018 | Expired or cancelled cancelled Jan 2026 | 1830 17th St | install temporary vinyl window filmDetails
install temporary vinyl window film | $1,813 | |
| Mar 28, 2018 | Never finaled issued Apr 2018, no final | 1830 17th St | Oliver & Company Inc. | to comply with complaint 201845721 - emergency shoring permit - work completed dec 2017 - collapsed roof truss shored to assure safety and stability. permanent repair under seperate permit.Details
to comply with complaint 201845721 - emergency shoring permit - work completed dec 2017 - collapsed roof truss shored to assure safety and stability. permanent repair under seperate permit. | $2,500 |
| Dec 30, 2013 | Completed final sign-off Jul 2014 | 1830 17th St | Qse Construction | previously broken truss from old bad wood was repaird on one end only in 1994 & should have been upgraded on other end to replace bad wood. this is now done. ** maher: compliance with ordinance# 155-13 not required **Details
previously broken truss from old bad wood was repaird on one end only in 1994 & should have been upgraded on other end to replace bad wood. this is now done. ** maher: compliance with ordinance# 155-13 not required ** | $4,150 |
Who worked here
Everyone with a license on these permits, by role, with how many permits each is on.
- Contractors
- Oliver & Company Inc. (3), Aquamatic Fire Protection (2), A V F Systems Inc, Qse Construction
- Architects
- Matt Stromberg (2)
- Engineers
- Carl Milsum (2), Brian Kehoe, Eunice Yoon, Jason Lau
Find contractors for work like this
Starts from the last permit filed here; change it to describe your own project. Results cover every building: the city does not class this parcel as single-family, two-family or apartments.