Block 0294, lot 009
250 Post St
- City’s use
- Commercial Retail
- Built
- 1908
- Stories
- 3
- Units
- 1
- Rooms
- 4 bathrooms
- Building
- 38,475 sq ft
- Lot
- 11,473 sq ft
- Zoning
- C3R
- Construction type
- C
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
43 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Feb 20, 2026 | Completed final sign-off Jul 2026 | 250 Post St | Roofing Logistics | re-roofing: work at front uppder ledge roof and front canopy roof, remove 431 sq ft of existing roofing and dispose of property, install 431 sq ft of 1/4 inch fire rated board over the existing plywood, install 431 sq ft of 60 mil gaf pvc single ply material, no asphalt or torch downDetails
re-roofing: work at front uppder ledge roof and front canopy roof, remove 431 sq ft of existing roofing and dispose of property, install 431 sq ft of 1/4 inch fire rated board over the existing plywood, install 431 sq ft of 60 mil gaf pvc single ply material, no asphalt or torch down | $40,800 |
| Feb 28, 2023 | Completed final sign-off Feb 2025 | 246 Post St | accessible business entrance program per ordinance 51-16 in respponse to mandatory disability access improvement abe# 202301035933Details
accessible business entrance program per ordinance 51-16 in respponse to mandatory disability access improvement abe# 202301035933 | $1,000 | |
| Feb 28, 2023 | Completed final sign-off Feb 2025 | 250 Post St | accessible business entrance program per ordinance 51-16 in response to mandatory disability access improvement abe 202301035931. adding door bottom & thresholdDetails
accessible business entrance program per ordinance 51-16 in response to mandatory disability access improvement abe 202301035931. adding door bottom & threshold | $1,000 | |
| Oct 23, 2019 | Completed final sign-off Oct 2020 | 250 Post St | Legacy Mechanical & Energy Services, Inc | like for like replacement of (1) box car a/c unit & fluid cooler n/a maherDetails
like for like replacement of (1) box car a/c unit & fluid cooler n/a maher | $190,000 |
| Jul 30, 2014 | Never finaled issued Jul 2014, no final | 250 Post St | street space & mta permitDetails
street space & mta permit | ||
| Feb 21, 2013 | Expired or cancelled cancelled Jan 2026 | 250 Post St | Dickinson Cameron Construction Company I | remodel of main sale area. new counters and cabinets and finishes, lighting minor mechanical workDetails
remodel of main sale area. new counters and cabinets and finishes, lighting minor mechanical work | $100,000 |
| Nov 9, 2012 | Completed final sign-off Nov 2012 | 250 Post St | Atlantis Fire Protection | revise existing sprinklers to accomodate new ceiling in (3) rooms. add (3) new pendent sprinklers total.Details
revise existing sprinklers to accomodate new ceiling in (3) rooms. add (3) new pendent sprinklers total. | $1,200 |
| Nov 6, 2012 | Never finaled issued Nov 2012, no final | 250 Post St | Simplexgrinnell Lp. | basement floor fire alarm system tenant improvement - 1 duct smoke w/relay, 1 strobe & 1 horn/strobe. new matrix of operation shown- ref pa #2012.0925.0578.Details
basement floor fire alarm system tenant improvement - 1 duct smoke w/relay, 1 strobe & 1 horn/strobe. new matrix of operation shown- ref pa #2012.0925.0578. | $3,500 |
| Sep 25, 2012 | Never finaled issued Oct 2012, no final | 250 Post St | Dickinson Cameron Construction Company I | basement level-construction of new workshop in (e) space. new finishes & fixtures. new hvac, electrical & plumbing. *steamer hood - sprinkler on seperate permitDetails
basement level-construction of new workshop in (e) space. new finishes & fixtures. new hvac, electrical & plumbing. *steamer hood - sprinkler on seperate permit | $120,000 |
| Feb 17, 2012 | Completed final sign-off Apr 2013 | 250 Post St | West Builders Inc. | barrier removal. existing stair exit door exceeds ada opening pressure. existing door and frame to be removed and replaced to meet adaDetails
barrier removal. existing stair exit door exceeds ada opening pressure. existing door and frame to be removed and replaced to meet ada | $10,000 |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/10/23/6196 to obtain final inspection. all work has been completed.Details
renew pa# 2007/10/23/6196 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/06/26/5214 to obtain final inspection. all work has been completed.Details
renew pa# 2007/06/26/5214 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/04/19/9149 to obtain final inspection. all work has been completed.Details
renew pa# 2007/04/19/9149 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/06/26/5212 to obtain final inspection. all work has been completed.Details
renew pa# 2007/06/26/5212 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/06/26/5150 to obtain final inspection. all work has been completed.Details
renew pa# 2007/06/26/5150 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/04/10/8400 to obtain final inspection. all work has been completed.Details
renew pa# 2007/04/10/8400 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/06/20/4519 to obtain final inspection. all work has been completed.Details
renew pa# 2007/06/20/4519 to obtain final inspection. all work has been completed. | |
| Apr 10, 2009 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | renew pa# 2007/07/18/7102 to obtain final inspection. all work has been completed.Details
renew pa# 2007/07/18/7102 to obtain final inspection. all work has been completed. | |
| Oct 23, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Simplex Grinnell | alternate location for fire alarm devicesDetails
alternate location for fire alarm devices | $1,100 |
| Jul 18, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | change corridor rating from 1 hour to non rated. revision to pa# 200706204519Details
change corridor rating from 1 hour to non rated. revision to pa# 200706204519 | |
| Jun 26, 2007 | Completed final sign-off Oct 2007 | 250 Post St | Thomas Swan Sign Co Inc | erect electric single faced new signDetails
erect electric single faced new sign | |
| Jun 26, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Simplex Grinnell | revision to permit application 20070410240 addition of: 8 duct detectors, 6 control modules for elevator recall and security door override, 1 heat detector in elev. machical room. 1 iam & relay for whut trip power supervision. add 1 h/s, to 1st fl.Details
revision to permit application 20070410240 addition of: 8 duct detectors, 6 control modules for elevator recall and security door override, 1 heat detector in elev. machical room. 1 iam & relay for whut trip power supervision. add 1 h/s, to 1st fl. | $5,000 |
| Jun 26, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Thomas Swan Sign Co Inc | erect electric indirect new signDetails
erect electric indirect new sign | |
| Jun 20, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | basement partition revison to 200701171819, lighting relocations only, no additonal lights, work work at vestibule, reception and corridor b07Details
basement partition revison to 200701171819, lighting relocations only, no additonal lights, work work at vestibule, reception and corridor b07 | |
| Apr 19, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Dpw Inc. | modify extg basement and ground floor for new walls and ceilingsDetails
modify extg basement and ground floor for new walls and ceilings | $20,000 |
| Apr 10, 2007 | Expired or cancelled expired Apr 2009 | 250 Post St | Simplex Grinnell | 1st floor & basement-fire alarm t.i., 1st floor and basement. addition of 1 remote ann., 1 ps, 1 smoke detector, 7 duct detectors, 13 strobes, 5 horn strobes and 1 nal extender panel.Details
1st floor & basement-fire alarm t.i., 1st floor and basement. addition of 1 remote ann., 1 ps, 1 smoke detector, 7 duct detectors, 13 strobes, 5 horn strobes and 1 nal extender panel. | $14,000 |
| Jan 17, 2007 | Completed final sign-off Apr 2009 | 250 Post St | Shawmut Woodworking & Supply Inc | complete interior renovation inc., equip., finishes. work includes new hvac, electrical, plumbing. basement, ground, mezz. exterior storefront will include new entry. demo & barricade appl#200612139735.Details
complete interior renovation inc., equip., finishes. work includes new hvac, electrical, plumbing. basement, ground, mezz. exterior storefront will include new entry. demo & barricade appl#200612139735. | $750,000 |
| Dec 13, 2006 | Never finaled issued Dec 2006, no final | 250 Post St | Shawmut Woodworking & Supply Inc | non structural demolition of vacant retail space, removal of post st. entry doors. construction of temporary post st. sidewalk barricade. per ab-017 (interior demolition only).Details
non structural demolition of vacant retail space, removal of post st. entry doors. construction of temporary post st. sidewalk barricade. per ab-017 (interior demolition only). | $30,000 |
| Oct 27, 2006 | Never finaled issued Oct 2006, no final | 250 Post St | street spaceDetails
street space | ||
| Aug 31, 2006 | Never finaled issued Oct 2006, no final | 250 Post St | Thomas Swan Sign Co Inc | add (2) banner signs w/ vinyl banners to post street storefront.Details
add (2) banner signs w/ vinyl banners to post street storefront. | $8,000 |
| Aug 31, 2006 | Never finaled issued Oct 2006, no final | 250 Post St | Thomas Swan Sign Co Inc | to erect a double faced, electrical, projecting sign.Details
to erect a double faced, electrical, projecting sign. | $2,000 |
| Jul 12, 2006 | Never finaled issued Jul 2006, no final | 250 Post St | street spaceDetails
street space | ||
| Sep 12, 2005 | Expired or cancelled expired May 2006 | 250 Post St | revision to connection 5 thru 8 on 51.1 per letter from engineering date 9/9/05. per pa 200502105228Details
revision to connection 5 thru 8 on 51.1 per letter from engineering date 9/9/05. per pa 200502105228 | ||
| Aug 8, 2005 | Never finaled issued Sep 2005, no final | 250 Post St | Gold Coast Signs Inc | erect sign for non electric, wall, single faced.Details
erect sign for non electric, wall, single faced. | $10,000 |
| Aug 8, 2005 | Expired or cancelled expired May 2006 | 250 Post St | Gold Coast Signs Inc | erect sign for electric, wall,single face.Details
erect sign for electric, wall,single face. | $700 |
| Aug 4, 2005 | Expired or cancelled expired May 2006 | 250 Post St | minor revision to stairvestbule configuration from approved permit#200502105228.Details
minor revision to stairvestbule configuration from approved permit#200502105228. | $1,000 | |
| Jun 27, 2005 | Never finaled issued Sep 2005, no final | 250 Post St | non structural replacement of front doors & adjacent display windows.Details
non structural replacement of front doors & adjacent display windows. | $28,000 | |
| May 4, 2005 | Never finaled issued Jul 2005, no final | 250 Post St | Ayoob & Peery Plumbing Co Inc | basement 1st & 2nd floor.s (add and relocated fire sprinkler heads per t.i)Details
basement 1st & 2nd floor.s (add and relocated fire sprinkler heads per t.i) | $50,500 |
| May 3, 2005 | Never finaled issued Aug 2005, no final | 250 Post St | Simplex Grinnell | provide & install new initiating & notification devices for the new t.i. see equipment list on sheetDetails
provide & install new initiating & notification devices for the new t.i. see equipment list on sheet | $14,500 |
| Apr 21, 2005 | Never finaled issued Apr 2005, no final | 250 Post St | street spaceDetails
street space | ||
| Feb 10, 2005 | Never finaled issued Apr 2005, no final | 250 Post St | interior t.i. new mechanical, lighting systems, new partitions. minor structural floor infil on fl 1Details
interior t.i. new mechanical, lighting systems, new partitions. minor structural floor infil on fl 1 | $750,000 | |
| Dec 22, 2004 | Completed final sign-off May 2005 | 250 Post St | on all floors & basement non-structural demo to expose base bldgf condition prior to apply forDetails
on all floors & basement non-structural demo to expose base bldgf condition prior to apply for | $78,000 | |
| Sep 15, 2003 | Expired or cancelled expired Jun 2006 | 250 Post St | A Better Image/G.W. Laine | erect:non-electric, wall, single faced, non-illuminated new signDetails
erect:non-electric, wall, single faced, non-illuminated new sign | $1,800 |
Find contractors for work like this