Block 0195, lot 020
838 Kearny St
- City’s use
- Commercial Misc
- Built
- 2005
- Stories
- 5
- Rooms
- 30 bathrooms
- Building
- 51,000 sq ft
- Lot
- 7,271 sq ft
- Zoning
- CRNC
- Construction type
- D
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
34 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Mar 28, 2023 | Completed final sign-off Apr 2023 | 838 Kearny St | Priority Architectural Graphics Dba Prio | 1 evacuation plan map level b1 for fire review onlyDetails
1 evacuation plan map level b1 for fire review only | $425 |
| Jan 18, 2023 | Completed final sign-off Nov 2023 | 838 Kearny St | Plant Construction Co, Lp | revision to pa#202102174826. scope of work includes closure of extg exit to ils alley and use of ext exit to gibbs lane and new storage space at gym. all lower levelDetails
revision to pa#202102174826. scope of work includes closure of extg exit to ils alley and use of ext exit to gibbs lane and new storage space at gym. all lower level | |
| Jan 9, 2023 | Completed final sign-off Jan 2023 | 838 Kearny St | San Francisco Fire Protection | as-built - install 2 additional monitor modules to monitor (e) duct detectors. add 2 new relays for fsd and air handler #1. add 1 speaker/strobe. ref 202208090201.Details
as-built - install 2 additional monitor modules to monitor (e) duct detectors. add 2 new relays for fsd and air handler #1. add 1 speaker/strobe. ref 202208090201. | |
| Oct 17, 2022 | Completed final sign-off Jan 2023 | 838 Kearny St | San Francisco Fire Protection | addition to existing fire alarm. install power supply for new notification devices, amplifier for new notification devices, smoke detectors, strobes lights, relm modules. the actual scope is to correct the number of relays to 7.Details
addition to existing fire alarm. install power supply for new notification devices, amplifier for new notification devices, smoke detectors, strobes lights, relm modules. the actual scope is to correct the number of relays to 7. | $10,000 |
| Aug 9, 2022 | Completed final sign-off Jan 2023 | 838 Kearny St | San Francisco Fire Protection | addition to existing fire alarm. install remote power supply, amplifier, smoke detectors, speaker strobes, relay modules. ref permit 201402289566.Details
addition to existing fire alarm. install remote power supply, amplifier, smoke detectors, speaker strobes, relay modules. ref permit 201402289566. | $10,000 |
| Jul 28, 2022 | Completed final sign-off Nov 2023 | 838 Kearny St | Pioneer Fire Inc. | relocate fire sprinklers due to new ceiling & wall configuration in basement, new gym, 3 new classrooms, & 2 student restrooms. ref ti# 202102174826.Details
relocate fire sprinklers due to new ceiling & wall configuration in basement, new gym, 3 new classrooms, & 2 student restrooms. ref ti# 202102174826. | $18,000 |
| Jul 8, 2022 | Completed final sign-off Nov 2023 | 838 Kearny St | Canning Electric Inc | new electrical wiring for supply and install of new lighting and switches/outlets in e basement of school for new gymDetails
new electrical wiring for supply and install of new lighting and switches/outlets in e basement of school for new gym | $250,000 |
| Feb 18, 2022 | Completed final sign-off Mar 2022 | 838 Kearny St | remove and replacement of (e) 42in tall code compliant guardrails at levels 3 & 4 egress balconies with new compliant, 7ft tall painted stell guardrails.Details
remove and replacement of (e) 42in tall code compliant guardrails at levels 3 & 4 egress balconies with new compliant, 7ft tall painted stell guardrails. | $120,000 | |
| Feb 17, 2021 | Completed final sign-off Nov 2023 | 838 Kearny St | Plant Construction Co, Lp | project comprises of the interior fit out of the basement floor including 1 new gymnasium, 3 new classrooms and 2 new student restrooms.Details
project comprises of the interior fit out of the basement floor including 1 new gymnasium, 3 new classrooms and 2 new student restrooms. | $3,000,000 |
| Dec 5, 2019 | Completed final sign-off Feb 2020 | 838 Kearny St | San Francisco Fire Protection | as built to pa 2017-0717-2053 add existing door holder on 4th fl to reflect the job site and new door holder on 5th fl & tie-in to (e) relay. ref pa 2014-0228-9566Details
as built to pa 2017-0717-2053 add existing door holder on 4th fl to reflect the job site and new door holder on 5th fl & tie-in to (e) relay. ref pa 2014-0228-9566 | $2,000 |
| Aug 31, 2018 | Completed final sign-off Jul 2019 | 838 Kearny St | to obtain final inspection for work approved under pa# 9623103s & 2019-07-16-2848. all work is complete.Details
to obtain final inspection for work approved under pa# 9623103s & 2019-07-16-2848. all work is complete. | ||
| Jun 12, 2018 | Completed final sign-off Aug 2018 | 838 Kearny St | San Francisco Fire Protection | as builts to 201707172053 due to interior remodeling on 3rd and 4th flrs nbew notification devices will be installed for complete coverage and tie in to (e) circuits ti 201804116034 maher naDetails
as builts to 201707172053 due to interior remodeling on 3rd and 4th flrs nbew notification devices will be installed for complete coverage and tie in to (e) circuits ti 201804116034 maher na | $5,000 |
| May 7, 2018 | Completed final sign-off Aug 2018 | 838 Kearny St | Anderson, Rowe & Buckley, Inc. | 3rd and 4th floors: existing fire sprinkler system ti 3rd add speakers 2, relocate 18. 4th 1 added 14 relocate. arch 201804116034Details
3rd and 4th floors: existing fire sprinkler system ti 3rd add speakers 2, relocate 18. 4th 1 added 14 relocate. arch 201804116034 | $17,500 |
| Apr 11, 2018 | Completed final sign-off Sep 2018 | 838 Kearny St | Skyline Construction | complete 3 new clasrooms and 3 offices on third floor and 2 new class rooms and 1 single occupancy restroom on the 4th floor. n/a maher. complete buildout under previous permit with modifications.Details
complete 3 new clasrooms and 3 offices on third floor and 2 new class rooms and 1 single occupancy restroom on the 4th floor. n/a maher. complete buildout under previous permit with modifications. | $150,000 |
| Mar 23, 2018 | Completed final sign-off Jul 2019 | 838 Kearny St | revision to work under construction. show non-load bearing partitions not built on basement, 3rd, & 4th fl under approved arch addendum no. 7 #200907162848. maher naDetails
revision to work under construction. show non-load bearing partitions not built on basement, 3rd, & 4th fl under approved arch addendum no. 7 #200907162848. maher na | ||
| Dec 14, 2017 | Never finaled issued Dec 2017, no final | 838 Kearny St | Discount Signs & Neon Inc | install an non-electric single faced wall sign (st. mary's school). n/a maher ordinanceDetails
install an non-electric single faced wall sign (st. mary's school). n/a maher ordinance | $1,500 |
| Dec 14, 2017 | Never finaled issued Dec 2017, no final | 838 Kearny St | Discount Signs & Neon Inc | install an non-electric single faced wall sign (sterne school). n/a maher ordinanceDetails
install an non-electric single faced wall sign (sterne school). n/a maher ordinance | $1,500 |
| Jul 18, 2017 | Completed final sign-off Jul 2017 | 838 Kearny St | Anderson, Rowe & Buckley, Inc. | 2nd fl - add 5 and relocate 10 speakers; 3rd fl - add 5 & relocate 10, 4th fl - add 5 & relocate 8. ref pa 2017-0712-1696 (2nd & 3rd fls) and 2017-0703-0934 (4th fl)Details
2nd fl - add 5 and relocate 10 speakers; 3rd fl - add 5 & relocate 10, 4th fl - add 5 & relocate 8. ref pa 2017-0712-1696 (2nd & 3rd fls) and 2017-0703-0934 (4th fl) | $22,000 |
| Jul 17, 2017 | Completed final sign-off Jul 2017 | 838 Kearny St | San Francisco Fire Protection | due to classroom remodel-partially split into small classrooms on 2nd, 3rd and 4th flrs. 9 new speaker/strobes will be installed & tie-in to new power supply install on 2nd flr. in electrical room. connect new devices to (e) fire control panel on 1st flr. ti 2014-0703-0934 & 201402289566.Details
due to classroom remodel-partially split into small classrooms on 2nd, 3rd and 4th flrs. 9 new speaker/strobes will be installed & tie-in to new power supply install on 2nd flr. in electrical room. connect new devices to (e) fire control panel on 1st flr. ti 2014-0703-0934 & 201402289566. | $4,400 |
| Jul 13, 2017 | Expired or cancelled withdrawn Aug 2017 | 838 Kearny St | Anderson, Rowe & Buckley, Inc. | ti to existing fire sprinkler system on the 2nd, 34d, 5th, fl. due to relocating walls and ceilings in existing classroom, ref. to #201707030934.Details
ti to existing fire sprinkler system on the 2nd, 34d, 5th, fl. due to relocating walls and ceilings in existing classroom, ref. to #201707030934. | $2,000 |
| Jul 12, 2017 | Never finaled issued Jul 2017, no final | 838 Kearny St | renewal bpa #200907162848 and bpa #9623103s to complete work at basement, 2nd fl, 3rd fl and gym for final inspection. (recommence and completion of work)Details
renewal bpa #200907162848 and bpa #9623103s to complete work at basement, 2nd fl, 3rd fl and gym for final inspection. (recommence and completion of work) | $2,600,000 | |
| Jul 3, 2017 | Completed final sign-off Dec 2017 | 838 Kearny St | remodel class rooms, partially split into smaller rooms. new a/c units and lighing to accomodate the new layout. fire sprinkler and life safty under seperate permit. n/a for maherDetails
remodel class rooms, partially split into smaller rooms. new a/c units and lighing to accomodate the new layout. fire sprinkler and life safty under seperate permit. n/a for maher | $150,000 | |
| Dec 22, 2015 | Expired or cancelled cancelled Jan 2026 | 838 Kearny St | revision to 9623103 for 1939 sq ft of 4th fl of st marys school constructed but interior finishes never built. non structural walls to build out offices, meeting room, staff restroom, grades 3-8 science classroom. int finishes, flooring , ceiling, paint, tile, classroom, office, casework, and sinksDetails
revision to 9623103 for 1939 sq ft of 4th fl of st marys school constructed but interior finishes never built. non structural walls to build out offices, meeting room, staff restroom, grades 3-8 science classroom. int finishes, flooring , ceiling, paint, tile, classroom, office, casework, and sinks | $84,000 | |
| Mar 23, 2015 | Completed final sign-off May 2015 | 838 Kearny St | R M I Mechanical Contractors | provide ductwork and supply/return diffusers and connect to (e) ductwork fron an (e) air handling unit. add 3 exhaust fans for the restrooms and the staff kitchn. ref. appl. 2014.0610.8036. maher n/a.Details
provide ductwork and supply/return diffusers and connect to (e) ductwork fron an (e) air handling unit. add 3 exhaust fans for the restrooms and the staff kitchn. ref. appl. 2014.0610.8036. maher n/a. | $40,000 |
| Feb 23, 2015 | Completed final sign-off Jun 2015 | 838 Kearny St | San Francisco Fire Protection | 1st floor due to the interior remodel, one speaker/strobe & three strobes will be install for notification coveage. new devices will be tie-in to exist circuit & exist power supply panel. t.i. #2014.0610.8036. n/a maher ordinanceDetails
1st floor due to the interior remodel, one speaker/strobe & three strobes will be install for notification coveage. new devices will be tie-in to exist circuit & exist power supply panel. t.i. #2014.0610.8036. n/a maher ordinance | $1,000 |
| Feb 17, 2015 | Never finaled issued Feb 2015, no final | 838 Kearny St | Chris' Plumbing Inc | 1st - 4th floor fire sprinkler system t.i. - added 30 sprinklers, relocated sprinkler, removed 43 sprinklers. ref #201402289566. n/a maher ordinance 155-13Details
1st - 4th floor fire sprinkler system t.i. - added 30 sprinklers, relocated sprinkler, removed 43 sprinklers. ref #201402289566. n/a maher ordinance 155-13 | $18,500 |
| Jun 10, 2014 | Never finaled issued Dec 2014, no final | 838 Kearny St | Olive Construction Corp | revision of app #962303 construction of preschool space within existing school, original permit plan space for new chapel, chapel was not built interior construction only (to comply with maher ordinance - extended ordinance no.155-13 not required)Details
revision of app #962303 construction of preschool space within existing school, original permit plan space for new chapel, chapel was not built interior construction only (to comply with maher ordinance - extended ordinance no.155-13 not required) | $400,000 |
| May 16, 2014 | Completed final sign-off May 2014 | 838 Kearny St | San Francisco Fire Protection | as built to app#201402289566. remove duct detectors from plans. n/a for the maher ordinance #155-13Details
as built to app#201402289566. remove duct detectors from plans. n/a for the maher ordinance #155-13 | $1,000 |
| Feb 28, 2014 | Completed final sign-off May 2014 | 838 Kearny St | San Francisco Fire Protection | like for like voluntary fire system replacement. replace extg devices with new at the same location. connect extg notification appliances and sprinkler devices to new panel. nfpa72 central system monitoring.n/a for the maher ordinance #155-13Details
like for like voluntary fire system replacement. replace extg devices with new at the same location. connect extg notification appliances and sprinkler devices to new panel. nfpa72 central system monitoring.n/a for the maher ordinance #155-13 | $25,000 |
| Apr 27, 2011 | Expired or cancelled cancelled Jan 2026 | 838 Kearny St | required evacuation map signage for school-28 totalDetails
required evacuation map signage for school-28 total | $7,500 | |
| Feb 22, 2011 | Never finaled issued Feb 2011, no final | 838 Kearny St | street spaceDetails
street space | ||
| Feb 7, 2011 | Never finaled issued Feb 2011, no final | 838 Kearny St | add correct lot # to parcel for permits 2009-07-16-2848. 838 kearny street, previous 0195/013Details
add correct lot # to parcel for permits 2009-07-16-2848. 838 kearny street, previous 0195/013 | ||
| Feb 4, 2011 | Expired or cancelled cancelled Jan 2020 | 838 Kearny St | Herrero Builders Incorporated | as-builts, revision to approved pa# 2009/07/16/2848 (as builts) include minor interior alterations to fit field conditions. all changes in delta# 4. no exterior changes.Details
as-builts, revision to approved pa# 2009/07/16/2848 (as builts) include minor interior alterations to fit field conditions. all changes in delta# 4. no exterior changes. | |
| Jul 14, 2010 | Completed final sign-off Jul 2018 | 848 Kearny St | Siemens Industry, Inc. | new fire alarm system for the "st. mary's school" remodels on all floors fo the building. equipment adds are: 1 remote fire alarm panel, 1 amnunciator panel, 1 printer, 53 smoke detectors, 7 heat detectors, 5 duct detectors, 30 relay modules, 3 monitor modules, 15 pull stations,Details
new fire alarm system for the "st. mary's school" remodels on all floors fo the building. equipment adds are: 1 remote fire alarm panel, 1 amnunciator panel, 1 printer, 53 smoke detectors, 7 heat detectors, 5 duct detectors, 30 relay modules, 3 monitor modules, 15 pull stations, | $65,000 |
Who worked here
Everyone with a license on these permits, by role, with how many permits each is on.
- Contractors
- San Francisco Fire Protection (9), Anderson, Rowe & Buckley, Inc. (3), Discount Signs & Neon Inc (2), Plant Construction Co, Lp (2), Canning Electric Inc, Chris' Plumbing Inc, Herrero Builders Incorporated, Olive Construction Corp, Pioneer Fire Inc., Priority Architectural Graphics Dba Prio, R M I Mechanical Contractors, Siemens Industry, Inc., Skyline Construction
- Architects
- Pauline Souza (4), Gary Gee, Aia
- Engineers
- Rodolfo Bustos Iii (2), Stephen Shafter (2), Carl Milsum, Mark Robison
- Authorized agent-otherss
- Gary Gee
- Designers
- San Francisco Fire Protection (2)
Find contractors for work like this
Starts from the last permit filed here; change it to describe your own project. Results cover every building: the city does not class this parcel as single-family, two-family or apartments.