Ron Breckenridge Entrprses/Rb Petroleum
- Based in
- San Francisco
- On San Francisco permits
- Dec 2007 to Aug 2021
- Last 24 months
- 0 permits filed
22 permits since 2000: 16 completed, 6 never finaled.
Of the 6 never-finaled permits, 1 is 5 to 10 years old, 5 are over 10 years old.
This is the city’s permit record, not a license check. It does not show whether the state license is active, bonded or insured. How to read these records
Permits filed each year
How long permits take
Each point is the quarter the permits were filed, for all building permits across San Francisco. A median counts only permits that have finished, so the shaded recent quarters look faster than they will end up: their slow permits have not finished yet. Hover a point for the slowest 10%. Gaps mean fewer than 5 permits. A rise in the issue line is the city’s review backlog, not the contractor.
Most recent permits
| Filed | Outcome | Address | Work described on the permit | Declared cost |
|---|---|---|---|---|
| Aug 23, 2021 | Never finaled issued Aug 2021, no final | 551 26th Av | replace fuel system monitoring panel. replace 3 sensors, replace 1 liquid level probe, no replacement of any other components.Details
replace fuel system monitoring panel. replace 3 sensors, replace 1 liquid level probe, no replacement of any other components. | $7,000 |
| Mar 10, 2016 | Never finaled issued Apr 2016, no final | 375 Laguna Honda Bl | fuel supply line replacement in kind for back up generator. n/a for maherDetails
fuel supply line replacement in kind for back up generator. n/a for maher | $8,000 |
| Apr 8, 2015 | Never finaled issued Apr 2015, no final | 950 Bryant St | underground fuel storage tank repair (leaking) excavate tank, enter tank, pressurize annular. locate leak and repair. maher - not req'dDetails
underground fuel storage tank repair (leaking) excavate tank, enter tank, pressurize annular. locate leak and repair. maher - not req'd | $10,000 |
| Mar 5, 2014 | Never finaled issued Mar 2014, no final | 530 Sansome St | install new secondary containment pipe over existing fuel supply piping. no concrete removal required. all work to be done in existing pipe route.Details
install new secondary containment pipe over existing fuel supply piping. no concrete removal required. all work to be done in existing pipe route. | $1,500 |
| Aug 9, 2013 | Completed final sign-off Jun 2014 | 2901 Bryant St | new double-walled ul listed fuel pipes to be sleeved within existing 4" diameter underground pipes to existing fuel dispensers from existing underground storage tanks. no concrete work required.Details
new double-walled ul listed fuel pipes to be sleeved within existing 4" diameter underground pipes to existing fuel dispensers from existing underground storage tanks. no concrete work required. | $5,000 |
| Mar 16, 2012 | Never finaled issued Mar 2012, no final | 100 Martin Luther King Dr | replace fuel piping between dispensing pump & fuel storage tank (in-kind) no concrete cutting required.Details
replace fuel piping between dispensing pump & fuel storage tank (in-kind) no concrete cutting required. | $3,000 |
| Jan 17, 2012 | Completed final sign-off Feb 2013 | 800 Ulloa St | replace 2-4'0 sections of damaged fuel piping at under ground fuel storage tanks.Details
replace 2-4'0 sections of damaged fuel piping at under ground fuel storage tanks. | $1,000 |
| Jan 11, 2012 | Completed final sign-off Feb 2012 | 1000 Ocean Av | replace spill bucket and fill tank. no new pipingDetails
replace spill bucket and fill tank. no new piping | $1,500 |
| Jul 8, 2011 | Completed final sign-off Oct 2011 | 1935 32nd Av | install/replace gas pump fuel supply piping to 9e) underground tank.Details
install/replace gas pump fuel supply piping to 9e) underground tank. | $1,500 |
| May 18, 2010 | Completed final sign-off May 2010 | 601 Duboce Av | replace damaged xp suction piping (burried in ground approx 18") 20'-0" length to fuel tank-between office bldg. & patient care facility near duboce ave.Details
replace damaged xp suction piping (burried in ground approx 18") 20'-0" length to fuel tank-between office bldg. & patient care facility near duboce ave. | $2,500 |
| Nov 20, 2009 | Completed final sign-off Jan 2010 | 2601 Lombard St | valero gas station. install clean air seperator tank, concrete 4' x 8' x 8" deep mounting pad, and 4 bollards.Details
valero gas station. install clean air seperator tank, concrete 4' x 8' x 8" deep mounting pad, and 4 bollards. | $4,500 |
| Sep 18, 2009 | Completed final sign-off Dec 2009 | 701 Portola Dr | install healy air separation tank with 14ga enclosure at rear/southeast side of facility. sffd permit req - vapor recovery.Details
install healy air separation tank with 14ga enclosure at rear/southeast side of facility. sffd permit req - vapor recovery. | $10,000 |
| Aug 13, 2009 | Never finaled issued Aug 2009, no final | 375 Laguna Honda Bl | installation of air separation tank & concrete pad at existing re-fueling station.Details
installation of air separation tank & concrete pad at existing re-fueling station. | $10,000 |
| Mar 4, 2009 | Completed final sign-off Nov 2009 | 2990 San Bruno Av | installation of veeder root carbon canister for bay area air quality management district compliance, phase 2 evrDetails
installation of veeder root carbon canister for bay area air quality management district compliance, phase 2 evr | $15,000 |
| Mar 4, 2009 | Completed final sign-off Jul 2009 | 7355 Geary Bl | installation of veeder root carbon canister for bay area air quality management district compliance, phase 2 evrDetails
installation of veeder root carbon canister for bay area air quality management district compliance, phase 2 evr | $15,000 |
| Mar 4, 2009 | Completed final sign-off Jul 2009 | 376 Castro St | installation of veeder root carbon canister for bay area air quality management district complianceDetails
installation of veeder root carbon canister for bay area air quality management district compliance | $15,000 |
| Jan 27, 2009 | Completed final sign-off Aug 2009 | 598 Portola Dr | installation of baaqmd phase 2 veeder root carbon canister. attached at west side of bldg. venting system for underground tanks.Details
installation of baaqmd phase 2 veeder root carbon canister. attached at west side of bldg. venting system for underground tanks. | $10,000 |
| Jan 20, 2009 | Completed final sign-off Oct 2009 | 2901 Bryant St | installation veeder root carbon canister & fire resistant enclosure.Details
installation veeder root carbon canister & fire resistant enclosure. | $10,000 |
| Jan 20, 2009 | Completed final sign-off Jul 2009 | 4135 California St | installation of healy clean ari seperator per baaqmd phase ii evr compliance.Details
installation of healy clean ari seperator per baaqmd phase ii evr compliance. | $10,000 |
| Jan 20, 2009 | Completed final sign-off Sep 2009 | 1799 Ocean Av | installation of veeder root carbon canister, for baarmd phase v evr compliance on existing vent pipes adjacent to existing c-store/auto shop.Details
installation of veeder root carbon canister, for baarmd phase v evr compliance on existing vent pipes adjacent to existing c-store/auto shop. | $10,000 |
| Mar 28, 2008 | Completed final sign-off Apr 2008 | 2099 San Jose Av | change construction of vapor recovery enclosure from stainless steel to galvanized steel.Details
change construction of vapor recovery enclosure from stainless steel to galvanized steel. | |
| Dec 28, 2007 | Completed final sign-off Apr 2008 | 2099 San Jose Av | installation of healy clean air seperator for bay area air quality management district phase 2 evr complaiance.Details
installation of healy clean air seperator for bay area air quality management district phase 2 evr complaiance. | $15,000 |