Block 5992A, lot 059
501 Cambridge St
- City’s use
- Commercial Misc
- Built
- 1951
- Stories
- 4
- Rooms
- 86 bathrooms
- Building
- 138,518 sq ft
- Lot
- 190,861 sq ft
- Zoning
- RH1
- Construction type
- B
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
11 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Apr 16, 2026 | In progress issued Jun 2026 | 501 Cambridge St | Jensen Corp Landscape Contractors | ext improvements to (e) parking lot and playyard: removal of (e) pavement to create bioretention basin & permeable pavers to capture & treat stormwater. additionally underutilized parking lot at se corner will be depaved to be biohabitat. new drain & irrigation systems.Details
ext improvements to (e) parking lot and playyard: removal of (e) pavement to create bioretention basin & permeable pavers to capture & treat stormwater. additionally underutilized parking lot at se corner will be depaved to be biohabitat. new drain & irrigation systems. | $600,000 |
| Jun 12, 2024 | In progress issued Jul 2024 | 503 Cambridge St | Bay Cities Pyrotector Inc | modification of (e) notifier nfs2-3030 voice panel. addition of annunciator, devices, and appliances.Details
modification of (e) notifier nfs2-3030 voice panel. addition of annunciator, devices, and appliances. | $78,980 |
| Jul 11, 2022 | Completed final sign-off Jul 2022 | 501 Cambridge St | Bay Cities Pyrotector Inc | as built submittal to 201909181964Details
as built submittal to 201909181964 | |
| Sep 18, 2019 | Completed final sign-off Jul 2022 | 501 Cambridge St | Bay Cities Pyrotector Inc | basement,ground,1st,2nd,3rd flrs: voluntary fa system upgrade, main school bldg, bldg b(gym) & bldgs e&f(classrooms) to be networked w/ (e) notifier nfs2-3030 facp in dorm bldg via (3) ncm-w network cards. (9) power supplies, (244) smoke detectors w/bases, (3) heat detectors w/ bases, (6) beamDetails
basement,ground,1st,2nd,3rd flrs: voluntary fa system upgrade, main school bldg, bldg b(gym) & bldgs e&f(classrooms) to be networked w/ (e) notifier nfs2-3030 facp in dorm bldg via (3) ncm-w network cards. (9) power supplies, (244) smoke detectors w/bases, (3) heat detectors w/ bases, (6) beam | $291,321 |
| Sep 21, 2018 | Never finaled issued Apr 2019, no final | 501 Cambridge St | Tri Pointe Homes Inc | installation of temporary soldier pile & lagging retaining wall along southern property line of 495 cambridge. shoring will encroach onto 501 cambridge st. property by no more than 12". permission letter from 501 cambridge st. property included with submittal. ** maher: n/a **Details
installation of temporary soldier pile & lagging retaining wall along southern property line of 495 cambridge. shoring will encroach onto 501 cambridge st. property by no more than 12". permission letter from 501 cambridge st. property included with submittal. ** maher: n/a ** | $39,575 |
| Aug 30, 2018 | Never finaled issued Dec 2018, no final | 501 Cambridge St | retrofit of (e) bldg @ 2 locations (academic & theather bldg) that encroach on the adjacent property. cmu walls will be retrofitted to the ends of (e) portions of the bldgs for support of gravity & lateral loads, as well as providing a (n) staircase to the backside of the academic bldg. *maher n/a*Details
retrofit of (e) bldg @ 2 locations (academic & theather bldg) that encroach on the adjacent property. cmu walls will be retrofitted to the ends of (e) portions of the bldgs for support of gravity & lateral loads, as well as providing a (n) staircase to the backside of the academic bldg. *maher n/a* | $52,119 | |
| Jun 9, 2017 | Completed final sign-off May 2022 | 501 Cambridge St | Bay Cities Pyrotector Inc | basement, ground, 1st, 2nd & 3rd. fire alarm sys installation of 1 facp, 3 power supplies, 1 aes radio dialer, 11 pull stations, 1 monitor module, 42 smoke detectors, 36 heat detectors, 26 horn/strobes-wall, 1 control merlule, 28 low-frequency horn/strobes, 14 strobes-wall.Details
basement, ground, 1st, 2nd & 3rd. fire alarm sys installation of 1 facp, 3 power supplies, 1 aes radio dialer, 11 pull stations, 1 monitor module, 42 smoke detectors, 36 heat detectors, 26 horn/strobes-wall, 1 control merlule, 28 low-frequency horn/strobes, 14 strobes-wall. | $39,804 |
| Feb 14, 2017 | Completed final sign-off Nov 2017 | 501 Cambridge St | Good Construction | to comply with nov # 201644491. to legalize a chain link fence located on the roof of the property. the fence is approx 8 ft tall and is 120 ft in length.Details
to comply with nov # 201644491. to legalize a chain link fence located on the roof of the property. the fence is approx 8 ft tall and is 120 ft in length. | $6,000 |
| Feb 4, 2009 | Completed final sign-off Apr 2011 | 501 Cambridge St | Vulcan Fire Protection | remove obsolete kitchen fire system with ul-300 systemDetails
remove obsolete kitchen fire system with ul-300 system | $6,000 |
| Dec 8, 2000 | Completed final sign-off Feb 2001 | 501 Cambridge St | install 4 parking lot light poles & foundation. light installed under separate electrical permit.Details
install 4 parking lot light poles & foundation. light installed under separate electrical permit. | $3,000 | |
| May 24, 2000 | Expired or cancelled expired Dec 2001 | 501 Cambridge St | recoat existing basement ball covrtDetails