| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Aug 28, 2026 | In progress issued Aug 2026 | 950 Tennessee St | Bobcomm Llc Dba Pacific Das Llc. | replacing (e) amplifier to meet current sfdt standards. ref pa# 201712015291.Details
replacing (e) amplifier to meet current sfdt standards. ref pa# 201712015291. | $20,000 |
| Nov 14, 2022 | Never finaled issued Nov 2022, no final | 950 Tennessee St | Aquamatic Fire Protection | basement: modify 106 sidewall sprinklers to make them more recessed and less likely of possible damage at the request of the building owner. no underground work.Details
basement: modify 106 sidewall sprinklers to make them more recessed and less likely of possible damage at the request of the building owner. no underground work. | $9,400 |
| Aug 24, 2020 | Completed final sign-off Jan 2021 | 950 Tennessee St | Thompson Builders Corp | revision to issued pa# 202006048153 to correct sheet fp1 installation note# 8 to indicate 24" minumum pipe bury instead of 36". ** maher: n/a **Details
revision to issued pa# 202006048153 to correct sheet fp1 installation note# 8 to indicate 24" minumum pipe bury instead of 36". ** maher: n/a ** | |
| Jun 20, 2020 | Never finaled issued Jul 2020, no final | 950 Tennessee St | Thompson Builders Corp | rev to issued amep addenda pa# 201712015291-s2. for record purposes only to remove the handwritten, notation "global shutdown made on sheet m-001. meor statement & dbi confirmation that there is no air moving system in excess of 2000 cfm is shown on sheet m-0003. ** maher: n/a **Details
rev to issued amep addenda pa# 201712015291-s2. for record purposes only to remove the handwritten, notation "global shutdown made on sheet m-001. meor statement & dbi confirmation that there is no air moving system in excess of 2000 cfm is shown on sheet m-0003. ** maher: n/a ** | |
| Jun 11, 2020 | Never finaled issued Jun 2020, no final | 950 Tennessee St | street spaceDetails
street space | ||
| Jun 4, 2020 | Completed final sign-off Jan 2021 | 950 Tennessee St | Thompson Builders Corp | revision to pa# 2017-1201-5291 s3 fire sprinkler addendum.ductile iron piping acceptable for use for underground main piping can have a mechanical joint with mege-lugs in lieu of thrust blocks minimum pipe bury to be 24".Details
revision to pa# 2017-1201-5291 s3 fire sprinkler addendum.ductile iron piping acceptable for use for underground main piping can have a mechanical joint with mege-lugs in lieu of thrust blocks minimum pipe bury to be 24". | $3,000 |
| Feb 28, 2020 | Never finaled issued Feb 2020, no final | 950 Tennessee St | street spaceDetails
street space | ||
| Jan 3, 2020 | Never finaled issued Jan 2020, no final | 950 Tennessee St | Thompson Builders Corp | street spaceDetails
street space | |
| Oct 30, 2019 | Never finaled issued Oct 2019, no final | 950 Tennessee St | street spaceDetails
street space | ||
| Aug 26, 2019 | Never finaled issued Aug 2019, no final | 950 Tennessee St | street spaceDetails
street space | ||
| Jul 26, 2019 | Completed final sign-off Feb 2021 | 950 Tennessee St | Thompson Builders Corp | new low pressure fire hydrant for new construction on tennessee st ref pa 2017-1201-5291 (s)Details
new low pressure fire hydrant for new construction on tennessee st ref pa 2017-1201-5291 (s) | |
| Feb 14, 2019 | Never finaled issued Feb 2019, no final | 950 Tennessee St | street spaceDetails
street space | ||
| Aug 6, 2018 | Never finaled issued Aug 2018, no final | 950 Tennessee St | street spaceDetails
street space | ||
| May 2, 2018 | Completed final sign-off Jan 2021 | 950 Tennessee St | Thompson Builders Corp | temporary shoring & tiebacks to allow for new construction ref pa# 2017/12/01/5291-s. ** maher: n/a **Details
temporary shoring & tiebacks to allow for new construction ref pa# 2017/12/01/5291-s. ** maher: n/a ** | $380,000 |
| May 2, 2018 | Completed final sign-off Jan 2021 | 950 Tennessee St | Thompson Builders Corp | excavation. temporary excavation shoring for new constructio. ref pa# 2017/12/01/5291-s. ** maher: n/a **Details
excavation. temporary excavation shoring for new constructio. ref pa# 2017/12/01/5291-s. ** maher: n/a ** | $200,000 |
| Dec 1, 2017 | Completed final sign-off Sep 2018 | 950 Tennessee St | Ryan Engineering Inc | to demolish 1 story with mezzanne, industrial, parking lot.Details
to demolish 1 story with mezzanne, industrial, parking lot. | $50,000 |
| Dec 1, 2017 | Completed final sign-off Mar 2021 | 950 Tennessee St | Thompson Builders Corp, Aquamatic Fire Protection | to erect new 4 stories, 1 basement, type i-b, 100 units residential and parking bldg. (r-2,s-2) ** maher: n/a **Details
to erect new 4 stories, 1 basement, type i-b, 100 units residential and parking bldg. (r-2,s-2) ** maher: n/a ** | $35,000,000 |
| Jul 17, 2006 | Expired or cancelled expired Mar 2008 | 950 Tennessee St | Cal West Concrete Cutting Inc. | cut (e) floor slab ansd excavate rectangular pit. place rebar and forms and pour cast in place concrete for new printing press to be installed with anchor bolts.Details
cut (e) floor slab ansd excavate rectangular pit. place rebar and forms and pour cast in place concrete for new printing press to be installed with anchor bolts. | $38,000 |
| Sep 16, 2004 | Never finaled issued Sep 2004, no final | 950 Tennessee St | 21st Century Home Improvt | reroofingDetails
reroofing | $52,360 |