Block 1163, lot 026
301 Masonic Av
- City’s use
- Multi-Family Residential
- Built
- 1981
- Stories
- 2
- Units
- 2
- Rooms
- 5 bedrooms, 5 bathrooms
- Building
- 4,129 sq ft
- Lot
- 2,250 sq ft
- Zoning
- RH2
- Construction type
- D
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
8 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Aug 15, 2025 | In progress issued Aug 2025 | 301 Masonic Av | Gavin Construction Inc | dryrot repair per on-site inspections report #1974 items 9a and 10a. 9a: 3rd fl: remove approx. 16 sq ft of walkable roof membrane and repair subroof in kind. re-install membrane. 10a: (2nd floor) repair approx. 80 sq ft of dry-rotted framing in kind at window. re-cover wall with sheet rock in kind.Details
dryrot repair per on-site inspections report #1974 items 9a and 10a. 9a: 3rd fl: remove approx. 16 sq ft of walkable roof membrane and repair subroof in kind. re-install membrane. 10a: (2nd floor) repair approx. 80 sq ft of dry-rotted framing in kind at window. re-cover wall with sheet rock in kind. | $18,000 |
| Feb 27, 2025 | In progress issued Mar 2025 | 301 Masonic Av | Performance Systems Integration Inc | rev 202412116636- as builts for orignal fire alarm onlyDetails
rev 202412116636- as builts for orignal fire alarm only | $40,000 |
| Dec 11, 2024 | In progress issued Jan 2025 | 301 Masonic Av | Performance Systems Integration Inc | installion of 1 fire-like es-50 facu, 1 annunciator, 13 smoke detectors,, 6 heat detectors, 2 pull station, 1 water flow monitor module, 10 lf horns/strobes, 4 strobes, 1 ext. horn/strobe, 1 10amp power supply, 1 cellular communicator, and 1 document box, conduit, backboxes and wiring.voluntary instDetails
installion of 1 fire-like es-50 facu, 1 annunciator, 13 smoke detectors,, 6 heat detectors, 2 pull station, 1 water flow monitor module, 10 lf horns/strobes, 4 strobes, 1 ext. horn/strobe, 1 10amp power supply, 1 cellular communicator, and 1 document box, conduit, backboxes and wiring.voluntary inst | $40,000 |
| Aug 22, 2019 | Completed final sign-off Sep 2019 | 301 Masonic Av | Belfor Usa Group Inc | replace broken decorative corbel at 2nd floor pop out. in-kind replacement.Details
replace broken decorative corbel at 2nd floor pop out. in-kind replacement. | $2,200 |
| Jan 11, 2016 | Completed final sign-off Apr 2016 | 301 Masonic Av | American Vision Windows | fiber glass casment to match window profiles replace/retro-fit 44 windows and 1 swing french door. all same size and location, all fiber glass and some windows are visible from street u factor = .27 shgl=.22 all same operations as (e) except 3 windows change operation to casements to meet egressDetails
fiber glass casment to match window profiles replace/retro-fit 44 windows and 1 swing french door. all same size and location, all fiber glass and some windows are visible from street u factor = .27 shgl=.22 all same operations as (e) except 3 windows change operation to casements to meet egress | $44,682 |
| Oct 10, 2012 | Never finaled issued Oct 2012, no final | 301 Masonic Av | Sure Roofing Systems/R.O.Choy | reroofingDetails
reroofing | $16,800 |
| Nov 30, 2007 | Completed final sign-off Feb 2008 | 301 Masonic Av | Bevilacqua & Sons | to renew app #200701242472Details
to renew app #200701242472 | $2,700 |
| Jan 24, 2007 | Never finaled issued Jan 2007, no final | 301 Masonic Av | install new concrete raised footings at 4x4 postsof existing rear stairDetails
install new concrete raised footings at 4x4 postsof existing rear stair | $5,500 |
Find contractors for work like this