Block 0282, lot 022
726 Sutter St
- City’s use
- Commercial Misc
- Lot
- 26,629 sq ft
- Zoning
- RC4
- Construction type
- NA
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
13 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Jun 8, 2023 | Never finaled issued Jun 2023, no final | 726 Sutter St | Luminous Fire Alarm | the (e) fire alarm horns in the renovated guest rooms area being replaced with horn strobes.Details
the (e) fire alarm horns in the renovated guest rooms area being replaced with horn strobes. | $20,860 |
| Jan 13, 2023 | Completed final sign-off Jan 2024 | 750 Sutter St | Landmark Restorations Ltd | 7 units to be upgraded for accessbility standard. 12 units to be upgraded for person w/hearing & visual impairmants. (e) common areas on 1st fl to be updated. no catering/ no shared kitchen.Details
7 units to be upgraded for accessbility standard. 12 units to be upgraded for person w/hearing & visual impairmants. (e) common areas on 1st fl to be updated. no catering/ no shared kitchen. | $185,000 |
| Sep 17, 2020 | Completed final sign-off Jul 2021 | 750 Sutter St | American Building Group Inc | service fans and (e) heating boiler and cooling tower. replace (e) air handling units, condenserwater circulation pumps, expansion tanks, domestic boilers & storage tanks, and fan coil units w/ equivalent units.Details
service fans and (e) heating boiler and cooling tower. replace (e) air handling units, condenserwater circulation pumps, expansion tanks, domestic boilers & storage tanks, and fan coil units w/ equivalent units. | $180,000 |
| Aug 11, 2020 | Completed final sign-off Oct 2020 | 750 Sutter St | American Building Group Inc | re-roofing permit. comply with cool roof requirements.Details
re-roofing permit. comply with cool roof requirements. | $35,000 |
| Dec 10, 2009 | Never finaled issued Dec 2009, no final | 750 Sutter St | Siemens Industry, Inc. | 1st floor addition of one door release station & relay module for the floor 1 exit from the hotel's main lobby. the devices are connected onto the existing fire alarm system.Details
1st floor addition of one door release station & relay module for the floor 1 exit from the hotel's main lobby. the devices are connected onto the existing fire alarm system. | $900 |
| Oct 21, 2009 | Completed final sign-off Mar 2010 | 750 Sutter St | Webcor Construction Lp | barrier removal at front entry door by adding motorized door operators & request to exit sensor to push bottom,Details
barrier removal at front entry door by adding motorized door operators & request to exit sensor to push bottom, | $5,000 |
| May 20, 2009 | Completed final sign-off Jul 2009 | 726 Sutter St | Webcor Construction Lp | addition of 1 new 5 ton packaged rooftop ac unit and associated duct work to service extg one-story space.Details
addition of 1 new 5 ton packaged rooftop ac unit and associated duct work to service extg one-story space. | $50,000 |
| Feb 10, 2009 | Completed final sign-off Apr 2009 | 726 Sutter St | Webcor Construction Lp | revision to superstructure addendum #2 (2007-0307-5620/s2). provide structural & architectural (4 hr fire rating) details for 4hr seperationDetails
revision to superstructure addendum #2 (2007-0307-5620/s2). provide structural & architectural (4 hr fire rating) details for 4hr seperation | $80,000 |
| Dec 15, 2008 | Completed final sign-off Apr 2009 | 726 Sutter St | Webcor Construction Lp | ref pa#2007/03/07/5620.clarify approved plans submitted in plan review comments addendum 3 (04/22/08)shall supersede preapplication letter findings items 5/6 addressing improvements of canterbury ex central stair (002), north stair (004).see sheets a000,a070,a088,a110,a111,a112,a113, a120,a705,a708,Details
ref pa#2007/03/07/5620.clarify approved plans submitted in plan review comments addendum 3 (04/22/08)shall supersede preapplication letter findings items 5/6 addressing improvements of canterbury ex central stair (002), north stair (004).see sheets a000,a070,a088,a110,a111,a112,a113, a120,a705,a708, | |
| Dec 8, 2008 | Never finaled issued Dec 2008, no final | 726 Sutter St | street space permit only.Details
street space permit only. | ||
| Nov 25, 2008 | Completed final sign-off Apr 2009 | 750 Sutter St | Webcor Construction Lp | revision to addendum pa# 2007-0307-5620s (architectural addendum)-replace 2 (e) elevators with 1 new elevator. scope of work schall be identified as follows: architecture delta 5Details
revision to addendum pa# 2007-0307-5620s (architectural addendum)-replace 2 (e) elevators with 1 new elevator. scope of work schall be identified as follows: architecture delta 5 | |
| Jun 13, 2008 | Never finaled issued Jun 2008, no final | 726 Sutter St | street spaceDetails
street space | ||
| Apr 23, 2008 | Never finaled issued Apr 2008, no final | 726 Sutter St | street space permit only.Details
street space permit only. |
Who worked here
Everyone with a license on these permits, by role, with how many permits each is on.
- Contractors
- Webcor Construction Lp (5), American Building Group Inc (2), Landmark Restorations Ltd, Luminous Fire Alarm, Siemens Industry, Inc.
- Architects
- Scott Sullivan, Tom Lee
- Engineers
- Ming Chen, Ryan Paul January
Find contractors for work like this
Starts from the last permit filed here; change it to describe your own project. Results cover every building: the city does not class this parcel as single-family, two-family or apartments.