Block 0028, lot 014
1255 Columbus Ave
- City’s use
- Multi-Family Residential
- Built
- 2019
- Stories
- 5
- Units
- 22
- Rooms
- 55 bedrooms, 45 bathrooms
- Building
- 44,040 sq ft
- Lot
- 16,623 sq ft
- Zoning
- C2
- Construction type
- A
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
19 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Aug 16, 2023 | Completed final sign-off Sep 2023 | 1255 Columbus Av | San Francisco Fire Protection | to verify sound levels in sleeping areas comply with sffc 1103.7.6.1 indicating the dba readings are at least 75 dbaDetails
to verify sound levels in sleeping areas comply with sffc 1103.7.6.1 indicating the dba readings are at least 75 dba | |
| Apr 14, 2022 | Completed final sign-off Aug 2022 | 1255 Columbus Av | San Francisco Fire Protection | install new equipement to (e) sysem, install remote power supply, smoke detector, pull station, monitoring module, strobe lights.Details
install new equipement to (e) sysem, install remote power supply, smoke detector, pull station, monitoring module, strobe lights. | $10,000 |
| May 11, 2021 | Completed final sign-off Oct 2021 | 1255 Columbus Av | errcs upgrade - revision to pa# 2013-0614-9565 s3; 1. reprogram frequencies per ccsf dt 2. replace existing rooftop yagi antenna with panel antenna 3. re-test errcs per ab# 2.01 2019Details
errcs upgrade - revision to pa# 2013-0614-9565 s3; 1. reprogram frequencies per ccsf dt 2. replace existing rooftop yagi antenna with panel antenna 3. re-test errcs per ab# 2.01 2019 | ||
| Mar 10, 2020 | Never finaled issued Mar 2020, no final | 1255 Columbus Av | Capital Electric & Sign Co | 2 elec wall signs orangetheoryDetails
2 elec wall signs orangetheory | $8,500 |
| Dec 18, 2019 | Never finaled issued Dec 2019, no final | 1255 Columbus Av | Cal - West Fire Protection Specialist | fire sprinkler ti. ground fl. (orange theory fitness) 39 relocate fire sprinkler heads.Details
fire sprinkler ti. ground fl. (orange theory fitness) 39 relocate fire sprinkler heads. | $12,500 |
| Jun 6, 2019 | Completed final sign-off Aug 2022 | 1255 Columbus Av | Feather River Builders | ti for 3251 sq ft fitness studio (orange theory fitness) includes new mechanical systems, electrical systems accessible restrooms, interior & millwork.Details
ti for 3251 sq ft fitness studio (orange theory fitness) includes new mechanical systems, electrical systems accessible restrooms, interior & millwork. | $225,000 |
| Nov 5, 2018 | Never finaled issued Nov 2018, no final | 1255 Columbus Av | street spaceDetails
street space | ||
| Nov 5, 2018 | Completed final sign-off Jan 2019 | 1255 Columbus Av | Amplex Electrical Inc | iinstall a new fire alarm system to a new apartment bld ref 201306149565 maher na// will be compliant with 1103.7.6.1Details
iinstall a new fire alarm system to a new apartment bld ref 201306149565 maher na// will be compliant with 1103.7.6.1 | $28,000 |
| Apr 18, 2018 | Never finaled issued Apr 2018, no final | 1255 Columbus Av | street space w/mtaDetails
street space w/mta | ||
| Mar 6, 2018 | Completed final sign-off Nov 2018 | 1255 Columbus Av | Fong's Construction & Plumbing | install new 6" underground dedicated fire service, approx 55' linear ft of diclp, demand . fire sprinkler approved under #201708316584/r1 and arch #201306149565. 560 gpm @ 35 psi, 220 gpm @ 53 psi, maher na.Details
install new 6" underground dedicated fire service, approx 55' linear ft of diclp, demand . fire sprinkler approved under #201708316584/r1 and arch #201306149565. 560 gpm @ 35 psi, 220 gpm @ 53 psi, maher na. | $15,000 |
| Aug 31, 2017 | Completed final sign-off Dec 2018 | 1255 Columbus Av | Thorpe Design Inc | fire sprinklers and standpipes per nfpa 13/14 for ref pa 201306149565 s2, total 659 sprinklers, demand 558.7 gpm 42.4 psi, 169.4 gpm @ 52.8 psi. 4 story residential over 1 story basement, total 5 stories. 6" underground and bfp under sep permit(s). ref pa 201306149565 **maher n/a**Details
fire sprinklers and standpipes per nfpa 13/14 for ref pa 201306149565 s2, total 659 sprinklers, demand 558.7 gpm 42.4 psi, 169.4 gpm @ 52.8 psi. 4 story residential over 1 story basement, total 5 stories. 6" underground and bfp under sep permit(s). ref pa 201306149565 **maher n/a** | $49,425 |
| Dec 22, 2016 | Completed final sign-off Feb 2019 | 1255 Columbus Av | Pacific General Construction | ground improvement by compaction groutingDetails
ground improvement by compaction grouting | $150,000 |
| Dec 19, 2016 | Completed final sign-off Feb 2019 | 1255 Columbus Av | Pacific General Construction | revision to 201306149565 s1: minor structural revisions for foundation and retaining wall with revised geotechnical report. maher naDetails
revision to 201306149565 s1: minor structural revisions for foundation and retaining wall with revised geotechnical report. maher na | |
| Nov 3, 2016 | Completed final sign-off Feb 2019 | 1255 Columbus Av | Pacific General Construction, Sandbank Construction, Inc | revision to 201404012202. replace internal bracing system at beams 5-12 with internal rakers. see separarte permit for tiebacks into adj propertyDetails
revision to 201404012202. replace internal bracing system at beams 5-12 with internal rakers. see separarte permit for tiebacks into adj property | |
| Apr 1, 2014 | Completed final sign-off Feb 2019 | 1255 Columbus Av | Pacific General Construction | temporary shoring system to accomodate foundation for new construction under pa# 2013/06/14/9565's'.Details
temporary shoring system to accomodate foundation for new construction under pa# 2013/06/14/9565's'. | $270,000 |
| Nov 7, 2013 | Completed final sign-off Sep 2016 | 1255 Columbus Av | Pacific General Construction | to demolish 3 stories commercial building. ** maher: compliance with ordinance no# 155-13 not required **Details
to demolish 3 stories commercial building. ** maher: compliance with ordinance no# 155-13 not required ** | $157,000 |
| Jun 14, 2013 | Completed final sign-off Feb 2019 | 1255 Columbus Av | Pacific General Construction | to erect 4 stories, one basement, 20 units apartment with commercial and parking building.Details
to erect 4 stories, one basement, 20 units apartment with commercial and parking building. | $8,500,000 |
| Feb 18, 2009 | Never finaled issued Feb 2009, no final | 1275 Columbus Av | street space/sidewalk permitDetails
street space/sidewalk permit | ||
| Feb 20, 2003 | Completed final sign-off Mar 2003 | 1275 Columbus Av | The Lawson Roofing Co Inc. | reroofingDetails
reroofing | $21,000 |
Find contractors for work like this
Starts from the last permit filed here; change it to describe your own project. Results cover apartment buildings like this one.