Block 7281, lot 007
3500 Great Hwy
- City’s use
- Miscellaneous/Mixed-Use
- Lot
- 1,255,872 sq ft
- Zoning
- P
- Construction type
- NA
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
10 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Jul 23, 2025 | In progress issued Jul 2025 | 3500 Great Hy | Pyro-Comm Systems, Inc. | this is a new fire alarm sprinkler system, install 1st fl. (1) fire alarm control unit (1) cellular commicator, (1) smoke detector (8) monitor modules, (3) relay modules, (1) mini monitor modules (1) manual pull station (1) horn strobe-wall mount ref pa# 20201230229Details
this is a new fire alarm sprinkler system, install 1st fl. (1) fire alarm control unit (1) cellular commicator, (1) smoke detector (8) monitor modules, (3) relay modules, (1) mini monitor modules (1) manual pull station (1) horn strobe-wall mount ref pa# 20201230229 | $11,336 |
| Mar 21, 2024 | In progress filed Mar 2024, not yet issued | 3500 Great Hy | Monterey Mechanical Co | sfpuc mou proj#j-24-0570: at (e) wastewater facility concrete building 821 - install new standby diesel generator & fuel system.Details
sfpuc mou proj#j-24-0570: at (e) wastewater facility concrete building 821 - install new standby diesel generator & fuel system. | $320,000 |
| Mar 11, 2021 | Never finaled issued Jun 2021, no final | 3500 Great Hy | Value Fire Protection Inc | install (18) sprinklers in generator room.Details
install (18) sprinklers in generator room. | $18,500 |
| Dec 23, 2020 | Completed final sign-off Apr 2024 | 3500 Great Hy | Island Fire Protection Inc | install new automatic wet fire sprinkler system for elevator pit and machine room per nfpa 13. 2 total heads. underground per nfpa 24 and sprinkler monitoring per nfpa 72 under separate permits.Details
install new automatic wet fire sprinkler system for elevator pit and machine room per nfpa 13. 2 total heads. underground per nfpa 24 and sprinkler monitoring per nfpa 72 under separate permits. | $33,000 |
| Dec 3, 2020 | Completed final sign-off Jan 2026 | 3500 Great Hy | Johnson Controls Fire | install fire alarm system for sf wasteside recycled water treatment facility. install 3 new monitoring modules, replace 2 devices, install 1 additional circuit. fully sprinkled bldg.Details
install fire alarm system for sf wasteside recycled water treatment facility. install 3 new monitoring modules, replace 2 devices, install 1 additional circuit. fully sprinkled bldg. | $16,500 |
| Jan 18, 2019 | Completed final sign-off Apr 2024 | 3500 Great Hy | Island Fire Protection Inc | installation of new fire sprinkler system.Details
installation of new fire sprinkler system. | $40,000 |
| Jan 18, 2019 | Completed final sign-off Apr 2024 | 3500 Great Hy | Sabah International Incorporated | provide & install a (n) engineered total flooding ig-55 clean agent fire extinguishing system for the following space. bldg osp 510 sulfuric acid storage 510c. enclosure is not normally occupied. **maher n/a**Details
provide & install a (n) engineered total flooding ig-55 clean agent fire extinguishing system for the following space. bldg osp 510 sulfuric acid storage 510c. enclosure is not normally occupied. **maher n/a** | $81,698 |
| Apr 6, 2017 | Never finaled issued Apr 2017, no final | 3500 Great Hy | Phoenix Electric Co. | revision to pa#201701197496, making corrections to the address of the life safety devices. n/a ordinance #155-13Details
revision to pa#201701197496, making corrections to the address of the life safety devices. n/a ordinance #155-13 | |
| Jan 19, 2017 | Never finaled issued Feb 2017, no final | 3500 Great Hy | Phoenix Electric Co. | administrative permit to correct occupancy class for pa 2015-0323-1630. modifying occupancy class from b to f-1 moderate hazard inddustrial group.Details
administrative permit to correct occupancy class for pa 2015-0323-1630. modifying occupancy class from b to f-1 moderate hazard inddustrial group. | |
| Mar 23, 2015 | Completed final sign-off Oct 2018 | 3500 Great Hy | Pyro-Comm Systems, Inc. | new fire alarm system for existing water pump station to include: 1 facu 12 smoke detectors and 11 horn/strobes. maher n/a.Details
new fire alarm system for existing water pump station to include: 1 facu 12 smoke detectors and 11 horn/strobes. maher n/a. | $6,200 |
Who worked here
Everyone with a license on these permits, by role, with how many permits each is on.
- Contractors
- Island Fire Protection Inc (2), Phoenix Electric Co. (2), Pyro-Comm Systems, Inc. (2), Johnson Controls Fire, Monterey Mechanical Co, Sabah International Incorporated, Value Fire Protection Inc
- Architects
- Michael J. Pierron
- Engineers
- Chin C. Tey
Find contractors for work like this