Block 1173, lot 007
40 Loyola Ter
- City’s use
- Multi-Family Residential
- Built
- 1922
- Stories
- 3
- Units
- 2
- Rooms
- 5 bedrooms, 3 bathrooms
- Building
- 2,924 sq ft
- Lot
- 2,630 sq ft
- Zoning
- RH2
- Construction type
- D
From the assessor's latest secured roll, which can lag recent work. Lot plans, zoning and planning history on the city’s Property Information Map
Permits filed here
9 permits filed for this property since 2000.
| Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
|---|---|---|---|---|---|
| Nov 14, 2016 | Completed final sign-off Nov 2016 | 40 Loyola Tr | to obtain a final inspection for work approved under pa#9207375 & pa#201410229587 and 201301319164 all work is complete.Details
to obtain a final inspection for work approved under pa#9207375 & pa#201410229587 and 201301319164 all work is complete. | ||
| Nov 24, 2015 | Completed final sign-off Jun 2017 | 40 Loyola Tr | install fire suppression per nfpa 13d 2013 edition in lower level hall, mech area, coverage in garage 1. combo fire domestic underground include as wellDetails
install fire suppression per nfpa 13d 2013 edition in lower level hall, mech area, coverage in garage 1. combo fire domestic underground include as well | $8,000 | |
| Sep 21, 2015 | Never finaled issued Sep 2015, no final | 42 Loyola Tr | Cutler Construction | revision to original bpa#201406279740, specify five sprinklers on ground floor 13d, with combo meter, 6-8 sprinkler heads.Details
revision to original bpa#201406279740, specify five sprinklers on ground floor 13d, with combo meter, 6-8 sprinkler heads. | |
| Sep 11, 2015 | Expired or cancelled cancelled Jan 2026 | 42 Loyola Tr | Cutler Construction | revision to 201406279740. at gr fl keep door from bedroom to exit hallwayDetails
revision to 201406279740. at gr fl keep door from bedroom to exit hallway | |
| Oct 22, 2014 | Expired or cancelled expired Dec 2017 | 40 Loyola Tr | relocate furnace to closet in unit. add header for door. add small wallDetails
relocate furnace to closet in unit. add header for door. add small wall | $8,000 | |
| Jun 27, 2014 | Completed final sign-off Apr 2018 | 42 Loyola Tr | conversion of 270 sf garage space to habitable area. removal of unwarranted room. new bedroom & bath. replace window, new door, new skylight.Details
conversion of 270 sf garage space to habitable area. removal of unwarranted room. new bedroom & bath. replace window, new door, new skylight. | $40,000 | |
| Jan 31, 2013 | Expired or cancelled expired Dec 2017 | 42 Loyola Tr | not changing anything outside or anything structural, removing & replacing lath & plaster. adding a few outlets, same location, reframing existing closet upstairs/2nd flr, dropping/lowering ceiling in upstairs hallway for ductwork for (n) furnace in the (e) closet on the 2nd floor.Details
not changing anything outside or anything structural, removing & replacing lath & plaster. adding a few outlets, same location, reframing existing closet upstairs/2nd flr, dropping/lowering ceiling in upstairs hallway for ductwork for (n) furnace in the (e) closet on the 2nd floor. | $10,000 | |
| Jan 2, 2013 | Expired or cancelled cancelled Nov 2016 | 40 Loyola Tr | Markoff Structural Pest Control | upgrade existing furnace room by installing 5/8 sheetrock at interior. install anchor bolts at proper intervals 4 on center room 6'-8 x 8'-6'. replace existing 2 furnaces with new high efficency comfort 95/100 afue furnaces. location left rear of garage (same location as existing)Details
upgrade existing furnace room by installing 5/8 sheetrock at interior. install anchor bolts at proper intervals 4 on center room 6'-8 x 8'-6'. replace existing 2 furnaces with new high efficency comfort 95/100 afue furnaces. location left rear of garage (same location as existing) | $5,000 |
| Nov 16, 2012 | Completed final sign-off Feb 2013 | 40 Loyola Tr | Markoff Structural Pest Control | see attached report #12659 item #1 & 2Details
see attached report #12659 item #1 & 2 | $10,000 |
Find contractors for work like this
Starts from the last permit filed here; change it to describe your own project. Results cover two-family buildings like this one.