# 1375 Van Dyke Ave

Block 4828, lot 035. Page: https://www.permitgraph.org/a/4828/035

- City's use: Industrial
- Built: 1981
- Stories: 1
- Units: 3
- Rooms: 2 bathrooms
- Building: 7,500 sq ft
- Lot: 7,500 sq ft
- Zoning: M1
- Construction type: C

From the assessor's latest secured roll, which can lag recent work.

## Permits filed here

12 permits filed for this property since 2000.

| Permit | Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
| --- | --- | --- | --- | --- | --- | --- |
| [201804307800](https://www.permitgraph.org/p/201804307800) | Apr 30, 2018 | Completed: final sign-off Jun 2018 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) | [Jerry Caldwell](https://www.permitgraph.org/contractor/jerry-caldwell-957614) | installation of battery & inverter cabinet, monitoring and communication boxex, connecte via, circuit breaker in main service panel. all equipment to be install in (e) ele room | $4,000 |
| [201710030204](https://www.permitgraph.org/p/201710030204) | Oct 3, 2017 | Completed: final sign-off Nov 2017 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | 2/f- construction of non bearing interior wall, approx. 25 feet in length, one interior door. | $5,000 |
| [201407010284](https://www.permitgraph.org/p/201407010284) | Jul 1, 2014 | Completed: final sign-off Jul 2014 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | revision to bpa # 2012.05.02.9649 to install wood siding on the recessed facades of north elevation, all in kind, instead of stucco | $200 |
| [201404244129](https://www.permitgraph.org/p/201404244129) | Apr 24, 2014 | Completed: final sign-off Jun 2014 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) | [Johnson Controls Security Solutions Llc](https://www.permitgraph.org/contractor/johnson-controls-security-solutions-llc-977249) | tycois to install duct detector modules. connection to extg fire panel. facp dedicated water flow system. tie into exist (3) and (5) add on total (8) global shutdown, adding addressable modules to ne… | $4,000 |
| [M351327](https://www.permitgraph.org/p/M351327) | Oct 3, 2012 | Never finaled: issued Oct 2012, no final | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | street space with sidewalk repair |  |
| [201208288430](https://www.permitgraph.org/p/201208288430) | Aug 28, 2012 | Completed: final sign-off Oct 2012 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) | [Tyco Integrated Security](https://www.permitgraph.org/contractor/tyco-integrated-security-707408) | install 1 dedicated water flow panel as dialer, 1 pull station, 1 smoke detector, 3 modules for monitoring, 3 duct detectors, on roof. tie into floor switch on riser, tie into 2 butter fly valve as t… | $4,300 |
| [201205029649](https://www.permitgraph.org/p/201205029649) | May 2, 2012 | Completed: final sign-off Jul 2014 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | convert portion of building from warehouse s-2 (20) to lab/office b (10). adding 2nd floor within building shell. sprinklers to be submitted under separate permit. | $200,000 |
| [201112080336](https://www.permitgraph.org/p/201112080336) | Dec 8, 2011 | Completed: final sign-off Oct 2012 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) | [Mike Fire Protection](https://www.permitgraph.org/contractor/mike-fire-protection-837570) | install new fire sprinkler system for extg bldg. per nfpa 13 with new 4" fire service. approved for ord hz grp 2, 195 heads, 4" tap cwm 6" on van dyke | $40,000 |
| [201110197107](https://www.permitgraph.org/p/201110197107) | Oct 19, 2011 | Completed: final sign-off Oct 2012 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | revision to pa# 2010-1104-4375-revise roof mounted mechanical equipment. construction phase change to work approved |  |
| [201011044375](https://www.permitgraph.org/p/201011044375) | Nov 4, 2010 | Completed: final sign-off Oct 2012 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | change of use from s-2 to b (lab). tenant improvement. conversion of (e) 2-level warehouse to a lab/office space. | $75,000 |
| [201003107887](https://www.permitgraph.org/p/201003107887) | Mar 10, 2010 | Expired or cancelled: expired Oct 2012 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) |  | suite a. addition of new 2nd floor and access stair within existing suite. sprinklers required for second floor, per cbc 903.2.10 and 903.2.10.12. | $35,000 |
| [200201156981](https://www.permitgraph.org/p/200201156981) | Jan 15, 2002 | Completed: final sign-off Jan 2002 | [1375 Van Dyke Av](https://www.permitgraph.org/a/4828/035) | [The Lawson Roofing Co Inc.](https://www.permitgraph.org/contractor/the-lawson-roofing-co-inc-339053) | reroofing | $37,000 |

## Who worked here

Everyone with a license on these permits, by role, with how many permits each is on.

- Contractors: [Jerry Caldwell](https://www.permitgraph.org/contractor/jerry-caldwell-957614), [Johnson Controls Security Solutions Llc](https://www.permitgraph.org/contractor/johnson-controls-security-solutions-llc-977249), [Mike Fire Protection](https://www.permitgraph.org/contractor/mike-fire-protection-837570), [The Lawson Roofing Co Inc.](https://www.permitgraph.org/contractor/the-lawson-roofing-co-inc-339053), [Tyco Integrated Security](https://www.permitgraph.org/contractor/tyco-integrated-security-707408)
- Architects: [Laurie Erickson](https://www.permitgraph.org/professional/laurie-erickson-C24082)

---
Source: City and County of San Francisco building permit records (DataSF, https://data.sf.gov/), permits filed since 1 January 2000, reloaded nightly. Data as of 22 November 2026.
This is the text of https://www.permitgraph.org/a/4828/035.