# 200 Napoleon St

Block 4343, lot 004. Page: https://www.permitgraph.org/a/4343/004

- City's use: Industrial
- Built: 1948
- Stories: 1
- Rooms: 5 bathrooms
- Building: 28,300 sq ft
- Lot: 214,999 sq ft
- Zoning: M2
- Construction type: C

From the assessor's latest secured roll, which can lag recent work.

## Permits filed here

28 permits filed for this property since 2000.

| Permit | Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
| --- | --- | --- | --- | --- | --- | --- |
| [202409251602](https://www.permitgraph.org/p/202409251602) | Sep 25, 2024 | In progress: issued Mar 2025 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Cold Storage Manufacturing Inc](https://www.permitgraph.org/contractor/cold-storage-manufacturing-inc-304183) | remove cold storage insulated walls, floor insulation and refrigeration equipoemnt. revert to original warehouse. existing sprinklers, lights and fire alarm to remain in warehouse demo only ti under… | $400,000 |
| [201712045442](https://www.permitgraph.org/p/201712045442) | Dec 4, 2017 | Never finaled: issued Dec 2017, no final | [180 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Johnson Controls Security Solutions Llc](https://www.permitgraph.org/contractor/johnson-controls-security-solutions-llc-977249) | install new facu to replace (e) facp due to obsolescene and add a new ip fire communicator ar facu, reconnect all (e) dewvices to new facu. no other changes will be made to (e) system maher na | $1,300 |
| [201608235817](https://www.permitgraph.org/p/201608235817) | Aug 23, 2016 | Completed: final sign-off Aug 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | to obtain fifnal inspection for work approved under pa#201108152475. all work is complete. |  |
| [201608013837](https://www.permitgraph.org/p/201608013837) | Aug 1, 2016 | Completed: final sign-off Apr 2017 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Johnson Controls Security Solutions Llc](https://www.permitgraph.org/contractor/johnson-controls-security-solutions-llc-977249) | revision to ref pa 201606281138: replacing (e) fire alarm panel with new fire alarm panel. replace (e) fire keypads with new. reconnect all (e) devices to new fire alarm panel | $900 |
| [201606281138](https://www.permitgraph.org/p/201606281138) | Jun 28, 2016 | Never finaled: issued Jun 2016, no final | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Johnson Controls Security Solutions Llc](https://www.permitgraph.org/contractor/johnson-controls-security-solutions-llc-977249) | adding a zone expander module to existing fire alaram panel. (2) new water flow switches and (2) new tampers switches will be connected to the zone expander. | $800 |
| [201606039106](https://www.permitgraph.org/p/201606039106) | Jun 3, 2016 | Completed: final sign-off Apr 2017 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [S A Selover Const Operation](https://www.permitgraph.org/contractor/s-a-selover-const-operation-604973) | construction phase change to work approved under pa# 201603162202, add electrical plan and title-24 compliance documents. n/a ordinance #155-13 | $7,500 |
| [201605258387](https://www.permitgraph.org/p/201605258387) | May 25, 2016 | Completed: final sign-off Apr 2017 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [S A Selover Const Operation](https://www.permitgraph.org/contractor/s-a-selover-const-operation-604973) | access improvements: demo (e) non compliant platform lift and demo (e) stair @ main entrance. install new accessible platform lift and rebuild a new stair at main entrance, maher na | $40,000 |
| [201604215307](https://www.permitgraph.org/p/201604215307) | Apr 21, 2016 | Completed: final sign-off Dec 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Station 1 Fire Protection](https://www.permitgraph.org/contractor/station-1-fire-protection-706366) | adding fire sprinklers in new paint booth and mix room. t.i. app#2015-1215-5151. n/a for maher | $10,200 |
| [201603162202](https://www.permitgraph.org/p/201603162202) | Mar 16, 2016 | Completed: final sign-off Apr 2017 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [S A Selover Const Operation](https://www.permitgraph.org/contractor/s-a-selover-const-operation-604973) | construction phase changes to work approved under pa#201512155151, office layout changes and spray booth layout changes, delete note "mechanical and electrical under separate permit". n/a ordinance #… | $10,000 |
| [201512155151](https://www.permitgraph.org/p/201512155151) | Dec 15, 2015 | Completed: final sign-off Apr 2017 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [S A Selover Const Operation](https://www.permitgraph.org/contractor/s-a-selover-const-operation-604973) | 1st floor t.i. - install spray booth . mech & elect under separate permits. n/a maher ordinance | $50,000 |
| [201512145064](https://www.permitgraph.org/p/201512145064) | Dec 14, 2015 | Completed: final sign-off Aug 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | to obtain final inspection for work approved under pa#201109305940. all work is complete. n/a for maher. |  |
| [201512145060](https://www.permitgraph.org/p/201512145060) | Dec 14, 2015 | Completed: final sign-off Aug 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | to obtain final inspection for work approved under pa#201109305834. all work is complete. n/a for maher. |  |
| [201512145063](https://www.permitgraph.org/p/201512145063) | Dec 14, 2015 | Expired or cancelled: expired Aug 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | to obtain final inspection for work approved under pa#201108152475. all work is complete. n/a for maher. |  |
| [M466547](https://www.permitgraph.org/p/M466547) | Feb 26, 2014 | Never finaled: issued Feb 2014, no final | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | street space permit |  |
| [201402148632](https://www.permitgraph.org/p/201402148632) | Feb 14, 2014 | Completed: final sign-off Mar 2015 | [180 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Narrowback Construction Co.](https://www.permitgraph.org/contractor/narrowback-construction-co-579655) | replace existing exterior door to allow for raising of back of sidewalk as required by sfdpw per pending permit 11e-0478. compliance with ordinance #155-13 not required. | $1,000 |
| [201109305940](https://www.permitgraph.org/p/201109305940) | Sep 30, 2011 | Completed: final sign-off Feb 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [G P Fire Protection](https://www.permitgraph.org/contractor/g-p-fire-protection-771947) | relocate 3 upright sprinklers for new ductwork plenum | $2,400 |
| [201109305834](https://www.permitgraph.org/p/201109305834) | Sep 30, 2011 | Expired or cancelled: expired Aug 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Sausal Corporation](https://www.permitgraph.org/contractor/sausal-corporation-281425) | revision to pa# 2011-0815-2475-construction phase change to work already under way, demolish (e) non compliant stair & replace with new code compliant stairs | $2,500 |
| [201108152475](https://www.permitgraph.org/p/201108152475) | Aug 15, 2011 | Expired or cancelled: expired Aug 2016 | [190 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Sausal Corporation](https://www.permitgraph.org/contractor/sausal-corporation-281425) | change of use from (e) warehouse to (n) vehicle maintenace facility /repair garage with no toxic materials. work incl. demising wall, new exterioropennings, mech vent syst for vehicle exhaust, waste… | $80,000 |
| [200707096292](https://www.permitgraph.org/p/200707096292) | Jul 9, 2007 | Expired or cancelled: expired Mar 2013 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Ames-Billingsley, Inc.](https://www.permitgraph.org/contractor/ames-billingsley-inc-260873) | install 4 replacement windows. all visable from street. new windows to be brown aluminium casements to match center room. u-value .38 - .52 | $6,000 |
| [200602104316](https://www.permitgraph.org/p/200602104316) | Feb 10, 2006 | Completed: final sign-off Apr 2006 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Walschon Fire Protection Inc](https://www.permitgraph.org/contractor/walschon-fire-protection-inc-568438) | install new mains and branchline piping to supply dry pendant fire sprinkler in new freezer & cooler boxes. 148 sprinkler heads. | $34,000 |
| [200601051560](https://www.permitgraph.org/p/200601051560) | Jan 5, 2006 | Completed: final sign-off Apr 2006 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | to install new loading ramp at front of property. ada compliance as per 200512160545 as well as revision | $35,000 |
| [200512160545](https://www.permitgraph.org/p/200512160545) | Dec 16, 2005 | Completed: final sign-off Apr 2006 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | install new loading dock and add new interior frames and panels for new coolerr, freezer and processing units. | $30,000 |
| [200212133495](https://www.permitgraph.org/p/200212133495) | Dec 13, 2002 | Never finaled: issued Dec 2002, no final | [180 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Emerald Plbg & Fire Protection](https://www.permitgraph.org/contractor/emerald-plbg-fire-protection-767866) | provide fire sprinkler system to (e) system for new mezz. 14 heads | $2,000 |
| [200206038010](https://www.permitgraph.org/p/200206038010) | Jun 3, 2002 | Never finaled: issued Sep 2002, no final | [180 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | expansion of current offices/new bthrm/new entry of show room for doors and wndws/hndycap lift | $120,000 |
| [200104136756](https://www.permitgraph.org/p/200104136756) | Apr 13, 2001 | Completed: final sign-off May 2001 | [180 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Amwest Mechanical Inc](https://www.permitgraph.org/contractor/amwest-mechanical-inc-765873) | 3 new heads on (e) pipe schedule system | $400 |
| [200103204723](https://www.permitgraph.org/p/200103204723) | Mar 20, 2001 | Completed: final sign-off Mar 2001 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) | [Arrow Sign Company](https://www.permitgraph.org/contractor/arrow-sign-company-314794) | erect a non-electric, single faced wall sign |  |
| [200011034835](https://www.permitgraph.org/p/200011034835) | Nov 3, 2000 | Expired or cancelled: expired Jun 2001 | [200 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | modified loading ramp & protective curb. | $18,000 |
| [200003275413](https://www.permitgraph.org/p/200003275413) | Mar 27, 2000 | Completed: final sign-off May 2001 | [180 Napoleon St](https://www.permitgraph.org/a/4343/004) |  | installation of new accessible exits from warehouise #2 to comply w/ exiting/accessibility requireme | $81,834 |

## Who worked here

Everyone with a license on these permits, by role, with how many permits each is on.

- Contractors: [S A Selover Const Operation](https://www.permitgraph.org/contractor/s-a-selover-const-operation-604973) (4), [Johnson Controls Security Solutions Llc](https://www.permitgraph.org/contractor/johnson-controls-security-solutions-llc-977249) (3), [Sausal Corporation](https://www.permitgraph.org/contractor/sausal-corporation-281425) (2), [Ames-Billingsley, Inc.](https://www.permitgraph.org/contractor/ames-billingsley-inc-260873), [Amwest Mechanical Inc](https://www.permitgraph.org/contractor/amwest-mechanical-inc-765873), [Arrow Sign Company](https://www.permitgraph.org/contractor/arrow-sign-company-314794), [Cold Storage Manufacturing Inc](https://www.permitgraph.org/contractor/cold-storage-manufacturing-inc-304183), [Emerald Plbg & Fire Protection](https://www.permitgraph.org/contractor/emerald-plbg-fire-protection-767866), [G P Fire Protection](https://www.permitgraph.org/contractor/g-p-fire-protection-771947), [Narrowback Construction Co.](https://www.permitgraph.org/contractor/narrowback-construction-co-579655), [Station 1 Fire Protection](https://www.permitgraph.org/contractor/station-1-fire-protection-706366), [Walschon Fire Protection Inc](https://www.permitgraph.org/contractor/walschon-fire-protection-inc-568438)
- Architects: [Harvey Hacker](https://www.permitgraph.org/professional/harvey-hacker-C8520) (6), [James Terry](https://www.permitgraph.org/professional/james-terry-C34838)
- Engineers: [Meng Hsiu Chen](https://www.permitgraph.org/professional/meng-hsiu-chen-M19582), [Rodrigo Santos](https://www.permitgraph.org/professional/rodrigo-santos-2984)

---
Source: City and County of San Francisco building permit records (DataSF, https://data.sf.gov/), permits filed since 1 January 2000, reloaded nightly. Data as of 22 November 2026.
This is the text of https://www.permitgraph.org/a/4343/004.