# 1049 Howard St

Block 3731, lot 074. Page: https://www.permitgraph.org/a/3731/074

- City's use: Industrial
- Built: 1923
- Stories: 2
- Rooms: 4 bathrooms
- Building: 8,500 sq ft
- Lot: 4,247 sq ft
- Zoning: SLR
- Construction type: C

From the assessor's latest secured roll, which can lag recent work.

## Permits filed here

13 permits filed for this property since 2000.

| Permit | Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
| --- | --- | --- | --- | --- | --- | --- |
| [202112154500](https://www.permitgraph.org/p/202112154500) | Dec 15, 2021 | Completed: final sign-off Apr 2022 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) | [Abm Building Solutions Llc](https://www.permitgraph.org/contractor/abm-building-solutions-llc-976012) | replace (3) existing rooftop duct heaters. reconnect to existing electrical, gas, and duct. | $97,200 |
| [202103317662](https://www.permitgraph.org/p/202103317662) | Mar 31, 2021 | Completed: final sign-off Feb 2022 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) | [San Francisco Fire Protection](https://www.permitgraph.org/contractor/san-francisco-fire-protection-806216) | as-built fo permit application # 202103106246 addition of heat detectro in elevator machine room. addition of monitor and relay module for shuntrip elevator function. remove elevator fire hat functio… | $2,746 |
| [202103106246](https://www.permitgraph.org/p/202103106246) | Mar 10, 2021 | Completed: final sign-off Feb 2022 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) | [San Francisco Fire Protection](https://www.permitgraph.org/contractor/san-francisco-fire-protection-806216) | volutary fa replacement slc devices only in sprinklered building. replace of existing facp, smoke detectiors, pull stations. install new monitor modules, relay modules, radio communicator. | $18,162 |
| [201911127000](https://www.permitgraph.org/p/201911127000) | Nov 12, 2019 | Expired or cancelled: cancelled Aug 2023 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) | [San Francisco Fire Protection](https://www.permitgraph.org/contractor/san-francisco-fire-protection-806216) | replacement & upgrade instalation of fire alarm system in full sprinkler building, replace of (e) facu with new iid 300, smoke detectors, pull station, new modules n/a maher | $9,000 |
| [201406309985](https://www.permitgraph.org/p/201406309985) | Jun 30, 2014 | Completed: final sign-off Jul 2014 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) | [Fire Sentry Protection Services](https://www.permitgraph.org/contractor/fire-sentry-protection-services-849337) | kitchen hood fire suppression upgrade to ul300. n/a ordinance #155-13. | $6,400 |
| [201206192940](https://www.permitgraph.org/p/201206192940) | Jun 19, 2012 | Never finaled: issued Jun 2012, no final | [1049 Howard St](https://www.permitgraph.org/a/3731/074) |  | to obtain final inspection for work approved under pa#9606516. all work is complete. |  |
| [201206192941](https://www.permitgraph.org/p/201206192941) | Jun 19, 2012 | Never finaled: issued Jun 2012, no final | [1049 Howard St](https://www.permitgraph.org/a/3731/074) |  | to obtain final inspection for work approved under pa#9516662. all work is complete. |  |
| [201206192942](https://www.permitgraph.org/p/201206192942) | Jun 19, 2012 | Completed: final sign-off Feb 2014 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) |  | to obtain final inspection for work approved under pa#9605238. all work is complete. |  |
| [M180225](https://www.permitgraph.org/p/M180225) | Sep 18, 2009 | Never finaled: issued Sep 2009, no final | [1049 Howard St](https://www.permitgraph.org/a/3731/074) |  | street space & sidewalk permit. |  |
| [200509092473](https://www.permitgraph.org/p/200509092473) | Sep 9, 2005 | Completed: final sign-off May 2012 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) |  | comply with bid nov#200558014 for permanent increase in occupant loud of (e) homeless shelter originally approved under pa#9421315s.prevs occupant load 30 on 2nd floor, proposal occupant load 25 at 1… |  |
| [200202229859](https://www.permitgraph.org/p/200202229859) | Feb 22, 2002 | Completed: final sign-off Aug 2002 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) |  | barrier removal only (n) ada entry ramp + stairs. no work on (e) bldg facade or interior | $7,500 |
| [M12687](https://www.permitgraph.org/p/M12687) | May 15, 2000 | Expired or cancelled: expired Sep 2000 | [1053 Howard St](https://www.permitgraph.org/a/3731/074) |  | sidewalk repair |  |
| [20000124822](https://www.permitgraph.org/p/20000124822) | Jan 24, 2000 | Completed: final sign-off May 2000 | [1049 Howard St](https://www.permitgraph.org/a/3731/074) | [Saarman Construction,Ltd.](https://www.permitgraph.org/contractor/saarman-construction-ltd-450928) | remove & replace waterproofing membrane, basement & 2nd fl | $32,000 |

## Who worked here

Everyone with a license on these permits, by role, with how many permits each is on.

- Contractors: [San Francisco Fire Protection](https://www.permitgraph.org/contractor/san-francisco-fire-protection-806216) (3), [Abm Building Solutions Llc](https://www.permitgraph.org/contractor/abm-building-solutions-llc-976012), [Fire Sentry Protection Services](https://www.permitgraph.org/contractor/fire-sentry-protection-services-849337), [Saarman Construction,Ltd.](https://www.permitgraph.org/contractor/saarman-construction-ltd-450928)
- Architects: [Asian Neighborhood Design](https://www.permitgraph.org/professional/asian-neighborhood-design-C14136)
- Engineers: [David S Penney](https://www.permitgraph.org/professional/david-s-penney-M25077)
- Authorized agents: [2v Design 2v Design](https://www.permitgraph.org/professional/2v-design-2v-design-C28132)

---
Source: City and County of San Francisco building permit records (DataSF, https://data.sf.gov/), permits filed since 1 January 2000, reloaded nightly. Data as of 22 November 2026.