# 1161 Mission St

Block 3727, lot 103. Page: https://www.permitgraph.org/a/3727/103

- City's use: Commercial Office
- Built: 1924
- Stories: 5
- Rooms: 11 bathrooms
- Building: 74,000 sq ft
- Lot: 12,000 sq ft
- Zoning: MUO
- Construction type: C

From the assessor's latest secured roll, which can lag recent work.

## Permits filed here

131 permits filed for this property since 2000.

| Permit | Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
| --- | --- | --- | --- | --- | --- | --- |
| [201811296987](https://www.permitgraph.org/p/201811296987) | Nov 29, 2018 | Completed: final sign-off Dec 2018 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 3rd floor - unit 310. remove 3/4" line, replace w/ 1" line, replace 2 ssu and relocate 2 ssp at (n) ceiling | $6,000 |
| [201811085393](https://www.permitgraph.org/p/201811085393) | Nov 8, 2018 | Completed: final sign-off Jan 2019 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | interior ti for suite 310 the scope of work includes 2 offices & 2 phone booths w/ele | $128,000 |
| [201711204401](https://www.permitgraph.org/p/201711204401) | Nov 20, 2017 | Completed: final sign-off Jan 2018 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | 3rd flr: interior ti for suite 310. scope of work to include 1 new office. new floor material, paint and lighting maher na | $87,000 |
| [201711023005](https://www.permitgraph.org/p/201711023005) | Nov 2, 2017 | Completed: final sign-off Jan 2018 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | demo suite 310: interior non-bearing walls, cabinets, floor material and lighting per ab-017. maher na | $10,000 |
| [M834447](https://www.permitgraph.org/p/M834447) | Sep 22, 2017 | Never finaled: issued Sep 2017, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [M825107](https://www.permitgraph.org/p/M825107) | Aug 29, 2017 | Never finaled: issued Aug 2017, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [M766407](https://www.permitgraph.org/p/M766407) | Mar 7, 2017 | Never finaled: issued Jun 2017, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [M765871](https://www.permitgraph.org/p/M765871) | Mar 6, 2017 | Never finaled: issued Mar 2017, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit |  |
| [201610079847](https://www.permitgraph.org/p/201610079847) | Oct 7, 2016 | Never finaled: issued Oct 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 1/f & basement- as built drawing for pa# 201502249152. n/a ordinance #155-13 |  |
| [201609228590](https://www.permitgraph.org/p/201609228590) | Sep 22, 2016 | Completed: final sign-off Oct 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 3rd flr, suite 300 fire alarm add 5 horn/strobes, ref pa# 201609076942 mahr na | $2,500 |
| [M723987](https://www.permitgraph.org/p/M723987) | Sep 21, 2016 | Never finaled: issued Sep 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [201609076942](https://www.permitgraph.org/p/201609076942) | Sep 7, 2016 | Completed: final sign-off Nov 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | 3rd floor: interior ti for suite 300, new office wall plans include electrical. no plumbing or mech in scope. maher na | $138,651 |
| [201608195501](https://www.permitgraph.org/p/201608195501) | Aug 19, 2016 | Never finaled: issued Aug 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | demolition of carpet, baseboard, lights of suite 300. ab-017. | $2,500 |
| [M706387](https://www.permitgraph.org/p/M706387) | Jul 19, 2016 | Never finaled: issued Jul 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [201605117154](https://www.permitgraph.org/p/201605117154) | May 11, 2016 | Never finaled: issued May 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bay Cities Pyrotector Inc](https://www.permitgraph.org/contractor/bay-cities-pyrotector-inc-792704) | 4th floor & penthouse - as builts for pa #201603293279: show three (3) existing fsds; (mother's room area), local, heat0activated, not tied into fa system. n/a maher ordinance |  |
| [201605056710](https://www.permitgraph.org/p/201605056710) | May 5, 2016 | Expired or cancelled: cancelled Jan 2026 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Spediacci Construction Inc](https://www.permitgraph.org/contractor/spediacci-construction-inc-950948) | minor revision to pa 2015-1207-4277 addition/upgrade to second path of egress. floor layout to return to existing layout. maher na |  |
| [201604296017](https://www.permitgraph.org/p/201604296017) | Apr 29, 2016 | Completed: final sign-off Jun 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | g/f remove and replace sprinklers (3) pendents and (2) uprights. reroute piping to accommodate new bike rooms. t.i. pa#201604144814. n/a oridnance #155-13 | $2,000 |
| [M682587](https://www.permitgraph.org/p/M682587) | Apr 20, 2016 | Never finaled: issued Apr 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit |  |
| [201604144814](https://www.permitgraph.org/p/201604144814) | Apr 14, 2016 | Completed: final sign-off Nov 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | new ground floor bike room and soffit; maher n/a | $18,000 |
| [201604144813](https://www.permitgraph.org/p/201604144813) | Apr 14, 2016 | Never finaled: issued Apr 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | revision to permit 201509096481; garbage room, no (e)stair demo,no storage rm fence; maher n/a |  |
| [M679547](https://www.permitgraph.org/p/M679547) | Apr 6, 2016 | Never finaled: issued Apr 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space w/mta |  |
| [201603293279](https://www.permitgraph.org/p/201603293279) | Mar 29, 2016 | Completed: final sign-off Feb 2018 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bay Cities Pyrotector Inc](https://www.permitgraph.org/contractor/bay-cities-pyrotector-inc-792704) | 4th floor & penthouse - fire alarm system modificaiton. install (1) remote power supply, (1) smoke detector w/base, (2) dual input modules, (18) horn/strobes, (1) wp strobe. ref #201510068976 & 20151… | $39,533 |
| [201603222737](https://www.permitgraph.org/p/201603222737) | Mar 22, 2016 | Completed: final sign-off Jun 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Electrical Services Co](https://www.permitgraph.org/contractor/electrical-services-co-410561) | 4th flr: lectrical lighting, title 24 and controlled outlets. ref app 2015 1006 8976. maher na | $340,000 |
| [201603222734](https://www.permitgraph.org/p/201603222734) | Mar 22, 2016 | Never finaled: issued Mar 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Electrical Services Co](https://www.permitgraph.org/contractor/electrical-services-co-410561) | 6th flr/penthouse: electrical lighting, title 24 and controlled outlets. ref app 2015 1207 4277. maher na | $45,000 |
| [201603162211](https://www.permitgraph.org/p/201603162211) | Mar 16, 2016 | Completed: final sign-off Jun 2018 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Select Mechanical Inc](https://www.permitgraph.org/contractor/select-mechanical-inc-928189) | furnish & install hvac system & duct work for the 6th floor and outdoor equipmen support ref pa 2015-1207-4277. maher na | $80,000 |
| [201603141907](https://www.permitgraph.org/p/201603141907) | Mar 14, 2016 | Expired or cancelled: cancelled Jan 2026 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Electrical Services Co](https://www.permitgraph.org/contractor/electrical-services-co-410561) | 4th & penthouse: electrical lighting, title 24 and controlled outlets, 4 th flr appn. 201510068976; penthouse appn. 201512074277, maher n/a | $385,000 |
| [201603141884](https://www.permitgraph.org/p/201603141884) | Mar 14, 2016 | Completed: final sign-off Jun 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Select Mechanical Inc](https://www.permitgraph.org/contractor/select-mechanical-inc-928189) | 4th floor: furnish and install hvac system as per design build plans with duct work. n/a for maher. ref app#201510068976 | $325,000 |
| [201603010878](https://www.permitgraph.org/p/201603010878) | Mar 1, 2016 | Completed: final sign-off May 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Fireout Sprnklr. Co.Inc/Fire Sprinklr Co](https://www.permitgraph.org/contractor/fireout-sprnklr-co-inc-fire-sprinklr-co-990652) | 4th floor & penthouse - fire sprinkler to remove existing sprinkler lines & heads & add new lines & heads in same location on 4th floor t.i. add new sprinkler heads to accomodate new t.i. on penthous… | $75,000 |
| [201602220149](https://www.permitgraph.org/p/201602220149) | Feb 22, 2016 | Never finaled: issued Feb 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | revision to pa 2015-0909-6481, for card readers. maher na |  |
| [201602190007](https://www.permitgraph.org/p/201602190007) | Feb 19, 2016 | Completed: final sign-off Mar 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | basement: add 2 card readers, add 6 control relays, add 5 interposing relays, add 5 duct smoke detectors. as built. ref app#201509096481. n/a for maher. | $1,526 |
| [201602179842](https://www.permitgraph.org/p/201602179842) | Feb 17, 2016 | Expired or cancelled: cancelled Jan 2026 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | to revise pa#201512074277 to reduce scope regarding existing fire escape. n/a ordinance #155-13 |  |
| [201602169624](https://www.permitgraph.org/p/201602169624) | Feb 16, 2016 | Never finaled: issued Feb 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Corish Electric Corporation](https://www.permitgraph.org/contractor/corish-electric-corporation-833237) | title 24 electrical. maher na. ref ew20151006501 | $150,000 |
| [M660187](https://www.permitgraph.org/p/M660187) | Feb 2, 2016 | Never finaled: issued Feb 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space. |  |
| [M652947](https://www.permitgraph.org/p/M652947) | Jan 7, 2016 | Never finaled: issued Jan 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [201512215602](https://www.permitgraph.org/p/201512215602) | Dec 21, 2015 | Never finaled: issued Jan 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [American Sign Installation Co](https://www.permitgraph.org/contractor/american-sign-installation-co-860168) | electric wall sign. compliance with maher ordinance no. 155-13 not required. | $5,600 |
| [201512215606](https://www.permitgraph.org/p/201512215606) | Dec 21, 2015 | Never finaled: issued Jan 2016, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [American Sign Installation Co](https://www.permitgraph.org/contractor/american-sign-installation-co-860168) | exterior banner sign. n/a maher ord. 155-13 | $2,000 |
| [201512074277](https://www.permitgraph.org/p/201512074277) | Dec 7, 2015 | Completed: final sign-off Jun 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Spediacci Construction Inc](https://www.permitgraph.org/contractor/spediacci-construction-inc-950948) | penthouse- interior tenant fit out of an office use including non-load bearing partitions, partial ceilings and finishes, single tenant occupancy. mechanical, electrical, electrical, plumbing & sprin… | $147,301 |
| [201510280999](https://www.permitgraph.org/p/201510280999) | Oct 28, 2015 | Completed: final sign-off Nov 2015 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | basement - relocate (4) and add (30) new sprinkler heads for ti. maher na | $12,000 |
| [201510210310](https://www.permitgraph.org/p/201510210310) | Oct 21, 2015 | Completed: final sign-off Mar 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | basement - add 3 strobes; n/a maher ord. # 155-13 | $9,000 |
| [201510149626](https://www.permitgraph.org/p/201510149626) | Oct 14, 2015 | Never finaled: issued Oct 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bay Cities Pyrotector Inc](https://www.permitgraph.org/contractor/bay-cities-pyrotector-inc-792704) | revision to original pa# 201507151551: as built, fire alarm devices per field corrections. maher na ref |  |
| [201510068976](https://www.permitgraph.org/p/201510068976) | Oct 6, 2015 | Completed: final sign-off Jun 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Spediacci Construction Inc](https://www.permitgraph.org/contractor/spediacci-construction-inc-950948) | 4th flr: interior tenant fit-out of an office use, including interior non-load bearing partitions, partial ceilings, lighting & finishes. floors to be single tenant occupancy; maher n/a | $539,000 |
| [201509116715](https://www.permitgraph.org/p/201509116715) | Sep 11, 2015 | Never finaled: issued Sep 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bakkenson Building Group](https://www.permitgraph.org/contractor/bakkenson-building-group-668663) | 4th floor: remove & discard (e) partitions and finishes, lights & ceilings. partial removal of mechanical, elect systems. interior demolition per ab-017. tenant improvement under separate permit. mah… | $20,000 |
| [201509096481](https://www.permitgraph.org/p/201509096481) | Sep 9, 2015 | Never finaled: issued Sep 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | interior tenant improvement for the basement including office and restroom, storage room. mechanical included. ref bpa201411060901 (elevator permit). | $185,000 |
| [201508184525](https://www.permitgraph.org/p/201508184525) | Aug 18, 2015 | Never finaled: issued Aug 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Arves Mechanical](https://www.permitgraph.org/contractor/arves-mechanical-987911) | hvac mechnical work - installation of ductwork, split vr systems, refrigerant piping with controls | $150,000 |
| [201508174374](https://www.permitgraph.org/p/201508174374) | Aug 17, 2015 | Never finaled: issued Aug 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Arves Mechanical](https://www.permitgraph.org/contractor/arves-mechanical-987911) | 5/f: hvac mechanical installation of ductwork, split system vr systems, refrigerated piping with controls | $150,000 |
| [201508124092](https://www.permitgraph.org/p/201508124092) | Aug 12, 2015 | Never finaled: issued Aug 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bioneer Builders](https://www.permitgraph.org/contractor/bioneer-builders-558061) | build platform for air conditioning units to be mounted on in roof area of building | $6,000 |
| [201508113928](https://www.permitgraph.org/p/201508113928) | Aug 11, 2015 | Never finaled: issued Aug 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Aaa Restaurant Fire Control/Dba Aaa Fire](https://www.permitgraph.org/contractor/aaa-restaurant-fire-control-dba-aaa-fire-719959) | demo /,odify (e) fire sprinklers system (maher na) | $92,000 |
| [201508073647](https://www.permitgraph.org/p/201508073647) | Aug 7, 2015 | Never finaled: issued Aug 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Arves Mechanical](https://www.permitgraph.org/contractor/arves-mechanical-987911) | 2/f-hvac mechanical work - installation of ductwork, split system vr systems, and refridgerant piping w/controls ref to t.i. pa #2015 0601 7583 & pa #2015 0812 4092 for equipment roof anchorage. mahe… | $150,000 |
| [201507302949](https://www.permitgraph.org/p/201507302949) | Jul 30, 2015 | Never finaled: issued Jul 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | replace existing basement stucco ceiling with 5/8' type x gypboard maher not req. ab-017 applies. | $10,000 |
| [201507151551](https://www.permitgraph.org/p/201507151551) | Jul 15, 2015 | Completed: final sign-off Oct 2015 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bay Cities Pyrotector Inc](https://www.permitgraph.org/contractor/bay-cities-pyrotector-inc-792704) | floor 1, 2 & 5: fire alarm system modification ti: addition of smoke detectors/bases (4) duct smoke detectors (2), input modules (4), relay modules (6), 1 heat detector/base (1), 24 hornstrobes (24),… | $40,852 |
| [201507080942](https://www.permitgraph.org/p/201507080942) | Jul 8, 2015 | Never finaled: issued Jul 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Meyerz Wirez Inc](https://www.permitgraph.org/contractor/meyerz-wirez-inc-987623) | electrical, title 24, plugs, switches, lights, wire, conduit, sub panel, panel upgrade. ref #201506017583. compliance with maher ordinance no 155-13 not required. | $27,000 |
| [201507080941](https://www.permitgraph.org/p/201507080941) | Jul 8, 2015 | Never finaled: issued Jul 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Meyerz Wirez Inc](https://www.permitgraph.org/contractor/meyerz-wirez-inc-987623) | lights, upgrade service, plugs, recepticals, title 24, wire elec ti, conduit, sub panels. ref #201506037950. compliance with maher ordinance no 155-13 not required. | $68,000 |
| [201507010487](https://www.permitgraph.org/p/201507010487) | Jul 1, 2015 | Completed: final sign-off Oct 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | suite 210 -two office rooms in suite 210; maher n/a | $8,000 |
| [201506037950](https://www.permitgraph.org/p/201506037950) | Jun 3, 2015 | Completed: final sign-off Apr 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bioneer Builders](https://www.permitgraph.org/contractor/bioneer-builders-558061) | 1st and 2nd floor: interior t.i. of full first floor and partial 2nd floor as office use, including interior non-load bearing partition, partial ceilings, lighting and finishes. mep, fire alarm and s… | $593,500 |
| [201506017583](https://www.permitgraph.org/p/201506017583) | Jun 1, 2015 | Never finaled: issued Jun 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bioneer Builders](https://www.permitgraph.org/contractor/bioneer-builders-558061) | 5th floor: interior ti of office including non load bearing partitions, partial ceiling, finishes. single tenant occupancy. mep/fire/life saftey under sep permit. maher na | $585,000 |
| [201504093266](https://www.permitgraph.org/p/201504093266) | Apr 9, 2015 | Completed: final sign-off Apr 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Bioneer Builders](https://www.permitgraph.org/contractor/bioneer-builders-558061) | remove and discard extg partitions/finishes, lighting and ceilings. partial removal of mechanical and electrical systems. n/a for maher. all work is non-structural only. this strucutre is not on umb… | $6,000 |
| [201502249152](https://www.permitgraph.org/p/201502249152) | Feb 24, 2015 | Never finaled: issued Feb 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | ground fl & bsmt. fire alarm t.i. for installation of new elevator including 5 smoke detectors & 3 relays. ref #2014.11.06.0901. n/a maher ordinance | $6,000 |
| [M559867](https://www.permitgraph.org/p/M559867) | Feb 17, 2015 | Never finaled: issued Feb 2015, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit (scaffolding) |  |
| [201411060901](https://www.permitgraph.org/p/201411060901) | Nov 6, 2014 | Completed: final sign-off Sep 2016 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | install new elevator from ground floor to basement level. maher n/a. building floors are vacant. future tenant improvement will be filed under seperate permit | $65,000 |
| [201407252146](https://www.permitgraph.org/p/201407252146) | Jul 25, 2014 | Completed: final sign-off Aug 2014 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | ste #210 - install one new offic. maher n/a. | $5,000 |
| [201406037321](https://www.permitgraph.org/p/201406037321) | Jun 3, 2014 | Completed: final sign-off Aug 2014 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | remove 6 heads and relocate 6 uprights. n/a for the maher ordinance #155-13. t.i. app# 201403130709 | $2,000 |
| [201405155921](https://www.permitgraph.org/p/201405155921) | May 15, 2014 | Completed: final sign-off Jun 2014 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | 2nd floor - demo of floor joists & wood subfloor , all non structuralon 2nd floor between column line a & b, 2-4. ( per ab-017). n/a maher ordinance #155-13 | $8,000 |
| [201403281968](https://www.permitgraph.org/p/201403281968) | Mar 28, 2014 | Completed: final sign-off Apr 2014 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Pribuss Engineering Inc](https://www.permitgraph.org/contractor/pribuss-engineering-inc-251241) | fire sprinkler ti: total 1 added upright sprinkler. ref pa #201403191157. compliance with ordinance #155-13 not required | $515 |
| [201403191157](https://www.permitgraph.org/p/201403191157) | Mar 19, 2014 | Completed: final sign-off Jan 2015 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Principal Builders Inc.](https://www.permitgraph.org/contractor/principal-builders-inc-829808) | 4th floor:t.i. to demo and construct new doors, partitions and finishes on 4th floor extg tenant space. mep, life safety and sprinklers on seperate permit as required.n/a for the maher ordinance #155… | $68,000 |
| [201403170885](https://www.permitgraph.org/p/201403170885) | Mar 17, 2014 | Never finaled: issued Mar 2014, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Acco Engineered Systems Inc. Dba Acco En](https://www.permitgraph.org/contractor/acco-engineered-systems-inc-dba-acco-en-120696) | 4th floor - install new 2 ton unit on roof for server room. compliance with ordinance #155-13 not required | $8,586 |
| [201403130655](https://www.permitgraph.org/p/201403130655) | Mar 13, 2014 | Completed: final sign-off Jun 2014 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | construction ti for suite 210. 4 new small offices and extend vinyl floor in open area. compliance with maher ordinance 155-13 does not apply | $18,500 |
| [201403130709](https://www.permitgraph.org/p/201403130709) | Mar 13, 2014 | Never finaled: issued Mar 2014, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) | interior demolition of suite 110. maher not requried. | $8,750 |
| [201310078712](https://www.permitgraph.org/p/201310078712) | Oct 7, 2013 | Completed: final sign-off Oct 2013 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | suite 220 - demo interior walls and carpet; ab-015 applies. | $5,000 |
| [201305177287](https://www.permitgraph.org/p/201305177287) | May 17, 2013 | Never finaled: issued May 2013, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | 4th floor-demolition of corridor that seperates tenant suites. close (e) corridor wall to combine 2 office suites | $16,000 |
| [201303121957](https://www.permitgraph.org/p/201303121957) | Mar 12, 2013 | Completed: final sign-off May 2013 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 2nd fl fire alarm t.i. adding 2 duct detectors. 2 control relays. 3 horn/strobes. | $6,000 |
| [201302120086](https://www.permitgraph.org/p/201302120086) | Feb 12, 2013 | Completed: final sign-off May 2013 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | unit #210 interior t.i. - work to include new walls, paint, floor material & cabinets counter. | $98,750 |
| [201301309130](https://www.permitgraph.org/p/201301309130) | Jan 30, 2013 | Completed: final sign-off Mar 2013 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | interior ti for suite 410. construction includes walls and cabinets | $14,000 |
| [201212115940](https://www.permitgraph.org/p/201212115940) | Dec 11, 2012 | Completed: final sign-off Dec 2012 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 4th floor: fire alarm t.i. on 4th floor adding 3 duct detectors,3 control relays, 6 horn strobes. ref: app# 201211134108 | $6,000 |
| [201211134108](https://www.permitgraph.org/p/201211134108) | Nov 13, 2012 | Completed: final sign-off Dec 2012 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | interior tenant improvement for suite 400 and 410. scope includes new walls, cabinets, finish floor materials, paint. in addition to arch, mechanical drawings included | $187,000 |
| [201210252780](https://www.permitgraph.org/p/201210252780) | Oct 25, 2012 | Completed: final sign-off Nov 2012 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | fire alarm for ti on the 3rd floor, ste 310 and 320. 1. duct detector (1) 1. control relay (1) 2. horn/strobes (7) t.i ref pa# 201209216361 | $5,000 |
| [201209210361](https://www.permitgraph.org/p/201209210361) | Sep 21, 2012 | Completed: final sign-off Jan 2013 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | interior t.i. for suite 310 and 320. the build out will incl. new offices, cabinets, finish flr mateial, paint, and mechanical | $129,000 |
| [201110257555](https://www.permitgraph.org/p/201110257555) | Oct 25, 2011 | Expired or cancelled: cancelled Jan 2026 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | convert (e) basement to 29-parking stalls 9n) ramp to (e) loading dock and (e) curb cut. mep under separate permit. | $50,000 |
| [201110257568](https://www.permitgraph.org/p/201110257568) | Oct 25, 2011 | Never finaled: issued Oct 2011, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | suite 120, revision to approved ti permit #200909307942. title 24 calculations required for signoff. |  |
| [201109225220](https://www.permitgraph.org/p/201109225220) | Sep 22, 2011 | Completed: final sign-off Oct 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | provide as -built lighting plan and title 24 lighting compliance per electrical inspection, bpa #20090819-5116, for reference |  |
| [201109195025](https://www.permitgraph.org/p/201109195025) | Sep 19, 2011 | Never finaled: issued Sep 2011, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | to obtain final inspection for work approved under app#200911191698. all work is complete. |  |
| [201109195005](https://www.permitgraph.org/p/201109195005) | Sep 19, 2011 | Never finaled: issued Sep 2011, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | to obtain final inspection for work approved under app#200909307942. all work is complete. |  |
| [201109023784](https://www.permitgraph.org/p/201109023784) | Sep 2, 2011 | Completed: final sign-off Oct 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | obtain final inspection for work approved under pa# 2009-0819-5116. all work complete |  |
| [201109023790](https://www.permitgraph.org/p/201109023790) | Sep 2, 2011 | Completed: final sign-off Oct 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | obtain final inspection for work approved under pa# 2009-1118-1601. all work complete |  |
| [201108263328](https://www.permitgraph.org/p/201108263328) | Aug 26, 2011 | Completed: final sign-off Dec 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 3rd floor-tenant improvement-adding 1 horn/strobes & 2 strobes | $5,000 |
| [201107220852](https://www.permitgraph.org/p/201107220852) | Jul 22, 2011 | Completed: final sign-off Sep 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [James Mechanical Co](https://www.permitgraph.org/contractor/james-mechanical-co-908259) | replace (e) ac-unit (split system) including duct work interior ti for suite 330-office. refer to 201107140256 permit. | $8,000 |
| [M273226](https://www.permitgraph.org/p/M273226) | Jul 19, 2011 | Never finaled: issued Jul 2011, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [201107190492](https://www.permitgraph.org/p/201107190492) | Jul 19, 2011 | Completed: final sign-off Dec 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) | 3rd floor fire alrm : add 2 duct detectors, 2 control relays | $3,000 |
| [201107140256](https://www.permitgraph.org/p/201107140256) | Jul 14, 2011 | Completed: final sign-off Sep 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | interior ti for suite 330 office space | $20,000 |
| [201106087650](https://www.permitgraph.org/p/201106087650) | Jun 8, 2011 | Completed: final sign-off Jul 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | #300, 3rd floor-refer to t.i. pa# 2011-0601-7161-mechanical work | $5,000 |
| [201106017161](https://www.permitgraph.org/p/201106017161) | Jun 1, 2011 | Completed: final sign-off Jul 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | interior ti for suite 300. no new walls, new gyp bd, paint carpet. | $10,000 |
| [201005182690](https://www.permitgraph.org/p/201005182690) | May 18, 2010 | Completed: final sign-off Jun 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | revision to 201004019499 to clarify mechanical plan layout at 2nd fl, unit 201. |  |
| [201005051820](https://www.permitgraph.org/p/201005051820) | May 5, 2010 | Never finaled: issued May 2010, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [International Commercial Awning, Inc.](https://www.permitgraph.org/contractor/international-commercial-awning-inc-645654) | suite 110: install individual aluminum letters sign over storefront. | $900 |
| [201004301467](https://www.permitgraph.org/p/201004301467) | Apr 30, 2010 | Completed: final sign-off May 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Diversified Fire Products](https://www.permitgraph.org/contractor/diversified-fire-products-627565) | fire alarm ti on the 2nd fl. for sunstream networks. 1 control relay, 2 duct detectors, 1 horn/strobe ( existing to be relocated) | $6,000 |
| [201004019499](https://www.permitgraph.org/p/201004019499) | Apr 1, 2010 | Completed: final sign-off Jul 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | unit#201 @ 2nd. flr.: interior t.i. for second floor included 4-offices and 1-conf. room. mechanical included. lighting under separate permit. (no sprinkler's will be move under this t.i.) | $8,000 |
| [200912163297](https://www.permitgraph.org/p/200912163297) | Dec 16, 2009 | Completed: final sign-off Feb 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Diversified Fire Products](https://www.permitgraph.org/contractor/diversified-fire-products-627565) | 5th floor tenant improvement - fire aalrm system, 2 duct detectors, 2 control relays, 2 interposing relays, 11 horn/strobes, 1 strobe.l | $8,680 |
| [200911191698](https://www.permitgraph.org/p/200911191698) | Nov 19, 2009 | Never finaled: issued Nov 2009, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [T J Constr Inc***Ck Id,Tie Liu Only*****](https://www.permitgraph.org/contractor/t-j-constr-inc-ck-id-tie-liu-only-797322) | suite #120 - revision to approved permit # 2009/0930/7942. additional infomation added to as builts per inspector's instructions and to clarify accessible entrance path of travel. |  |
| [200911181601](https://www.permitgraph.org/p/200911181601) | Nov 18, 2009 | Expired or cancelled: expired Oct 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [T J Constr Inc***Ck Id,Tie Liu Only*****](https://www.permitgraph.org/contractor/t-j-constr-inc-ck-id-tie-liu-only-797322) | suite #110 -revision to application #2009/0819/5116 to show as-built of cafe per inspector's instructions. |  |
| [200909307942](https://www.permitgraph.org/p/200909307942) | Sep 30, 2009 | Never finaled: issued Oct 2009, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [T J Constr Inc***Ck Id,Tie Liu Only*****](https://www.permitgraph.org/contractor/t-j-constr-inc-ck-id-tie-liu-only-797322) | tenant improvement to portion of ground floor space. classrooms, educational service space & storage. | $15,000 |
| [200909247624](https://www.permitgraph.org/p/200909247624) | Sep 24, 2009 | Completed: final sign-off May 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | 5th. flr. interior t.i. mep to be under separate permit. (new offces, conference rooms, reception area & open office area. | $40,000 |
| [200909247611](https://www.permitgraph.org/p/200909247611) | Sep 24, 2009 | Completed: final sign-off Jul 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | revision to appl. #2009/0609/0102. modification to original approved storefront. |  |
| [200908195116](https://www.permitgraph.org/p/200908195116) | Aug 19, 2009 | Expired or cancelled: expired Oct 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | on existing vacant space; construct a new cafe with h/c counter, seating & men/women restrooms @ ground floor. m/e/p under separate permit. | $45,000 |
| [200908114520](https://www.permitgraph.org/p/200908114520) | Aug 11, 2009 | Completed: final sign-off Aug 2011 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Diversified Fire Products](https://www.permitgraph.org/contractor/diversified-fire-products-627565) | fire alarm as built: addition of fsds per fd comment. ref 200812309292 | $9,714 |
| [200907213042](https://www.permitgraph.org/p/200907213042) | Jul 21, 2009 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | bathroom remodel in-kind @ penthouse; (n) tile, plumbing fixtures & entry glass door. | $11,000 |
| [200906090107](https://www.permitgraph.org/p/200906090107) | Jun 9, 2009 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | revision to appl #200811257342 - provide hvac unit per each suite. air distributio duct work system will be designed & completed at a later date. | $40,000 |
| [200906090102](https://www.permitgraph.org/p/200906090102) | Jun 9, 2009 | Completed: final sign-off Jul 2010 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | construct new ground floor store front retail, see reference pa #200804028614 for d.a. checklist. | $30,000 |
| [200906019459](https://www.permitgraph.org/p/200906019459) | Jun 1, 2009 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | to correct the use of the penthouse shown as storage under building permit #2009/0406/5657 to reflect the historical use as office. (n) vestibule @ penthouse | $10,000 |
| [200905229009](https://www.permitgraph.org/p/200905229009) | May 22, 2009 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [A.S.T.I. Services (Automatic Sprinkler)](https://www.permitgraph.org/contractor/a-s-t-i-services-automatic-sprinkler-742693) | install nine 5" flow switch, one on ground fl and two each on 2nd fl to 5th fl. | $1,500 |
| [M163045](https://www.permitgraph.org/p/M163045) | May 4, 2009 | Never finaled: issued May 2009, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit |  |
| [200904065657](https://www.permitgraph.org/p/200904065657) | Apr 6, 2009 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | repair gypboard and paint in penthoused per inspector request revision to app#200902121987 no change of use or occupancy. repair only. | $2,000 |
| [M158525](https://www.permitgraph.org/p/M158525) | Apr 1, 2009 | Never finaled: issued Apr 2009, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit only. |  |
| [200902252826](https://www.permitgraph.org/p/200902252826) | Feb 25, 2009 | Completed: final sign-off May 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Aries Construction Corp.](https://www.permitgraph.org/contractor/aries-construction-corp-825692) | refer to app#200703085803. remove the special inspection item#10. sprayed on fire proofing. because no sprayed-on fire proofing at this permit, use 5/8" gypbd wrap around steel beams. |  |
| [200902121987](https://www.permitgraph.org/p/200902121987) | Feb 12, 2009 | Completed: final sign-off May 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | delete accoustical insulation note from permit #2007/0308/5782 on 3rd.-4th. floor ceilings. removal of 5/8" type "x" from tenant side of corridor. |  |
| [M147008](https://www.permitgraph.org/p/M147008) | Jan 9, 2009 | Never finaled: issued Jan 2009, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit. |  |
| [200812309292](https://www.permitgraph.org/p/200812309292) | Dec 30, 2008 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Diversified Fire Products](https://www.permitgraph.org/contractor/diversified-fire-products-627565) | new fire alarm system for core of building. when tenant improvements are built- fire alarm permits required before occupancy | $23,215 |
| [200812108185](https://www.permitgraph.org/p/200812108185) | Dec 10, 2008 | Completed: final sign-off May 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | install of new ext awning at existing commercial build per plan. | $6,000 |
| [M144425](https://www.permitgraph.org/p/M144425) | Dec 4, 2008 | Never finaled: issued Dec 2008, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit only. |  |
| [200811257342](https://www.permitgraph.org/p/200811257342) | Nov 25, 2008 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | new mechanical system for (e) building to serve tenant spaces at each floor. hvac heat pump system. 300-400 pounds units. | $40,000 |
| [200811217149](https://www.permitgraph.org/p/200811217149) | Nov 21, 2008 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Aa Fire Systems Inc.](https://www.permitgraph.org/contractor/aa-fire-systems-inc-887999) | entire bldg-remove & relocate lines. install new wet stand pipe. | $23,000 |
| [200810234947](https://www.permitgraph.org/p/200810234947) | Oct 23, 2008 | Completed: final sign-off May 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | repair and glazing replacement for 4 (e) windows. repair (e) metal frames | $10,000 |
| [200810174448](https://www.permitgraph.org/p/200810174448) | Oct 17, 2008 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | revision to 200804028614: revise interior demising wall locations on all floors. new electrical closet on basement and 1st floor. relocate drinking fountain on 2nd-5th fl. | $2,000 |
| [200809232408](https://www.permitgraph.org/p/200809232408) | Sep 23, 2008 | Expired or cancelled: cancelled Jan 2026 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | construction of new interior steel staircase from basement thru 5th floor. | $80,000 |
| [200807287730](https://www.permitgraph.org/p/200807287730) | Jul 28, 2008 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Driggs & Wood Inc](https://www.permitgraph.org/contractor/driggs-wood-inc-388367) | fire sprinkler tenant improvement of lobby area. future phase 2 standpipe work will be interconnected with existing standpipes | $9,600 |
| [M117284](https://www.permitgraph.org/p/M117284) | Apr 24, 2008 | Never finaled: issued Apr 2008, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space |  |
| [200804048875](https://www.permitgraph.org/p/200804048875) | Apr 4, 2008 | Completed: final sign-off Mar 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [Diaz Roofing *** See Notes***](https://www.permitgraph.org/contractor/diaz-roofing-see-notes-811899) | reroofing. | $45,600 |
| [200804028614](https://www.permitgraph.org/p/200804028614) | Apr 2, 2008 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | all floors - revision to pa# 2007/03/08/5782 to include new demising walls in all floors and 2 restrooms on the ground floor. new exit passageway on first floor. | $50,000 |
| [200803046309](https://www.permitgraph.org/p/200803046309) | Mar 4, 2008 | Completed: final sign-off May 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) | [America West Builders](https://www.permitgraph.org/contractor/america-west-builders-823664) | replace 9 front windows on 3rd or 5th floors new windows to be wood and match existing configuration. side windows need to appear double hung | $20,000 |
| [M90365](https://www.permitgraph.org/p/M90365) | Oct 11, 2007 | Never finaled: issued Oct 2007, no final | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | street space permit |  |
| [200703085782](https://www.permitgraph.org/p/200703085782) | Mar 8, 2007 | Completed: final sign-off Aug 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | barrier removal, work to include new ada restrooms, ada drinking fountains, ada elevator buttons, somke enclosure for elevator, hallway. addition of new staircase. | $450,000 |
| [200703085803](https://www.permitgraph.org/p/200703085803) | Mar 8, 2007 | Completed: final sign-off May 2009 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | structural drawings for floor opening for staircase to appl#200703085782 only. | $50,000 |
| [200611157744](https://www.permitgraph.org/p/200611157744) | Nov 15, 2006 | Expired or cancelled: expired Jan 2008 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | demolition of (e) stud walls, finish floor materials, restrooms, lighting, please see drawing for full list. interior non-structural demo only under this permit. handicapped access issues to comply w… | $5,000 |
| [M14770](https://www.permitgraph.org/p/M14770) | Oct 13, 2000 | Expired or cancelled: expired Feb 2001 | [1161 Mission St](https://www.permitgraph.org/a/3727/103) |  | sidewalk repair |  |

## Who worked here

Everyone with a license on these permits, by role, with how many permits each is on.

- Contractors: [E J G A](https://www.permitgraph.org/contractor/e-j-g-a-989599) (16), [Red Hawk Fire & Security Ca Llc](https://www.permitgraph.org/contractor/red-hawk-fire-security-ca-llc-713099) (14), [Bay Cities Pyrotector Inc](https://www.permitgraph.org/contractor/bay-cities-pyrotector-inc-792704) (4), [Bioneer Builders](https://www.permitgraph.org/contractor/bioneer-builders-558061) (4), [Diversified Fire Products](https://www.permitgraph.org/contractor/diversified-fire-products-627565) (4), [Arves Mechanical](https://www.permitgraph.org/contractor/arves-mechanical-987911) (3), [Electrical Services Co](https://www.permitgraph.org/contractor/electrical-services-co-410561) (3), [Spediacci Construction Inc](https://www.permitgraph.org/contractor/spediacci-construction-inc-950948) (3), [T J Constr Inc***Ck Id,Tie Liu Only*****](https://www.permitgraph.org/contractor/t-j-constr-inc-ck-id-tie-liu-only-797322) (3), [American Sign Installation Co](https://www.permitgraph.org/contractor/american-sign-installation-co-860168) (2), [Meyerz Wirez Inc](https://www.permitgraph.org/contractor/meyerz-wirez-inc-987623) (2), [Select Mechanical Inc](https://www.permitgraph.org/contractor/select-mechanical-inc-928189) (2), [A.S.T.I. Services (Automatic Sprinkler)](https://www.permitgraph.org/contractor/a-s-t-i-services-automatic-sprinkler-742693), [Aa Fire Systems Inc.](https://www.permitgraph.org/contractor/aa-fire-systems-inc-887999), [Aaa Restaurant Fire Control/Dba Aaa Fire](https://www.permitgraph.org/contractor/aaa-restaurant-fire-control-dba-aaa-fire-719959), [Acco Engineered Systems Inc. Dba Acco En](https://www.permitgraph.org/contractor/acco-engineered-systems-inc-dba-acco-en-120696), [America West Builders](https://www.permitgraph.org/contractor/america-west-builders-823664), [Aries Construction Corp.](https://www.permitgraph.org/contractor/aries-construction-corp-825692), [Bakkenson Building Group](https://www.permitgraph.org/contractor/bakkenson-building-group-668663), [Corish Electric Corporation](https://www.permitgraph.org/contractor/corish-electric-corporation-833237), [Diaz Roofing *** See Notes***](https://www.permitgraph.org/contractor/diaz-roofing-see-notes-811899), [Driggs & Wood Inc](https://www.permitgraph.org/contractor/driggs-wood-inc-388367), [Fireout Sprnklr. Co.Inc/Fire Sprinklr Co](https://www.permitgraph.org/contractor/fireout-sprnklr-co-inc-fire-sprinklr-co-990652), [International Commercial Awning, Inc.](https://www.permitgraph.org/contractor/international-commercial-awning-inc-645654), [James Mechanical Co](https://www.permitgraph.org/contractor/james-mechanical-co-908259), [Pribuss Engineering Inc](https://www.permitgraph.org/contractor/pribuss-engineering-inc-251241), [Principal Builders Inc.](https://www.permitgraph.org/contractor/principal-builders-inc-829808)
- Architects: [Edward Gee](https://www.permitgraph.org/professional/edward-gee-C6586) (9), [Matthew Pietras](https://www.permitgraph.org/professional/matthew-pietras-C30302) (5), [Edward Gee](https://www.permitgraph.org/professional/edward-gee-C8586) (4), [Fillon Solis](https://www.permitgraph.org/professional/fillon-solis-C28828) (2), [Edward Gee](https://www.permitgraph.org/professional/edward-gee-C6566), [Patrick Perez](https://www.permitgraph.org/professional/patrick-perez-C30230), [Patrick Perez](https://www.permitgraph.org/professional/patrick-perez-30230)
- Engineers: [Craig Ristow](https://www.permitgraph.org/professional/craig-ristow-M30828), [Edward Gee](https://www.permitgraph.org/professional/edward-gee-C6586), [Lloyd Diehl](https://www.permitgraph.org/professional/lloyd-diehl-E9547)
- Designers: [Matthew Pietras](https://www.permitgraph.org/professional/matthew-pietras-C30302), [Weco Electrical Engeer. Inc.](https://www.permitgraph.org/professional/weco-electrical-engeer-inc-E9547)

---
Source: City and County of San Francisco building permit records (DataSF, https://data.sf.gov/), permits filed since 1 January 2000, reloaded nightly. Data as of 22 November 2026.
This is the text of https://www.permitgraph.org/a/3727/103.