# 466 Eddy St

Block 0334, lot 013. Page: https://www.permitgraph.org/a/0334/013

- City's use: Commercial Retail
- Built: 1900
- Stories: 1
- Units: 2
- Rooms: 1 bathroom
- Lot: 3,436 sq ft
- Zoning: RC4
- Construction type: C

From the assessor's latest secured roll, which can lag recent work.

## Permits filed here

15 permits filed for this property since 2000.

| Permit | Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
| --- | --- | --- | --- | --- | --- | --- |
| [M1065667](https://www.permitgraph.org/p/M1065667) | Apr 12, 2019 | Never finaled: issued Apr 2019, no final | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | street space |  |
| [201807305858](https://www.permitgraph.org/p/201807305858) | Jul 30, 2018 | Completed: final sign-off Jul 2019 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | mechanical room expansion on rooftop platform. ** maher: n/a ** | $25,000 |
| [201610271324](https://www.permitgraph.org/p/201610271324) | Oct 27, 2016 | Never finaled: issued Mar 2019, no final | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | change of use and condition use authorization per planning code requirements. for administrative purposes only, no work; maher n/a |  |
| [201608034092](https://www.permitgraph.org/p/201608034092) | Aug 3, 2016 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) | [San Francisco Fire Protection](https://www.permitgraph.org/contractor/san-francisco-fire-protection-806216) | sprinkler water flow & supervisory system. install new control unit, smoke detector above & pull station near panel in exit corridor area. install monitor modular to tie-in waterflow, tamper switch &… | $2,300 |
| [M683407](https://www.permitgraph.org/p/M683407) | Apr 25, 2016 | Never finaled: issued Apr 2016, no final | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | street space |  |
| [M648127](https://www.permitgraph.org/p/M648127) | Dec 18, 2015 | Never finaled: issued Dec 2015, no final | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | street space |  |
| [201510220451](https://www.permitgraph.org/p/201510220451) | Oct 22, 2015 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) | [International Fire Equip](https://www.permitgraph.org/contractor/international-fire-equip-253912) | installation of ul300 fire system reference pa 2015.1008.9185 / 2014.0401.2134 | $3,000 |
| [201510089185](https://www.permitgraph.org/p/201510089185) | Oct 8, 2015 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) | [Stevenson Mechanical Inc](https://www.permitgraph.org/contractor/stevenson-mechanical-inc-783316) | installation of kitchen type i hood. ref. to pa#201506058277. n/a ordinance #155-13 ul 300 system separate permit | $6,000 |
| [201509086417](https://www.permitgraph.org/p/201509086417) | Sep 8, 2015 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | change of occupancy from auto shop to restaurant/spa. revision only for change of description of the proposed use/legak use to permit pa 2014 0401 2134 |  |
| [201506128832](https://www.permitgraph.org/p/201506128832) | Jun 12, 2015 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | revision to pa #201404012134: redesign of structural moment frame. n/a for maher. | $1,000 |
| [201506058277](https://www.permitgraph.org/p/201506058277) | Jun 5, 2015 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | revision to app#201404012134. minor revision to kitchen layout. installation of kitchen hood type i will be filed under separate permit. n/a for maher. | $12,000 |
| [201504173987](https://www.permitgraph.org/p/201504173987) | Apr 17, 2015 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) | [Bay Cities Fire Protection](https://www.permitgraph.org/contractor/bay-cities-fire-protection-731222) | drop 33 sprinklers via ti 2014 0401 2134 maher - not req'd | $12,000 |
| [201404012134](https://www.permitgraph.org/p/201404012134) | Apr 1, 2014 | Completed: final sign-off Aug 2016 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | change of use. interior renovation of a 3,048 sqft, one story bldg from an auto garage to a holistic day spa. work includes restrooms, showers, spas, walls, hung ceilings, casework, finshes, and refi… | $85,000 |
| [M19457](https://www.permitgraph.org/p/M19457) | Mar 22, 2002 | Expired or cancelled: expired Jul 2002 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | side walk permit |  |
| [M18998](https://www.permitgraph.org/p/M18998) | Feb 19, 2002 | Expired or cancelled: expired Jun 2002 | [466 Eddy St](https://www.permitgraph.org/a/0334/013) |  | sidewalk |  |

## Who worked here

Everyone with a license on these permits, by role, with how many permits each is on.

- Contractors: [Bay Cities Fire Protection](https://www.permitgraph.org/contractor/bay-cities-fire-protection-731222), [International Fire Equip](https://www.permitgraph.org/contractor/international-fire-equip-253912), [San Francisco Fire Protection](https://www.permitgraph.org/contractor/san-francisco-fire-protection-806216), [Stevenson Mechanical Inc](https://www.permitgraph.org/contractor/stevenson-mechanical-inc-783316)
- Architects: [Michael Stanton](https://www.permitgraph.org/professional/michael-stanton-C11562)

---
Source: City and County of San Francisco building permit records (DataSF, https://data.sf.gov/), permits filed since 1 January 2000, reloaded nightly. Data as of 23 November 2026.
This is the text of https://www.permitgraph.org/a/0334/013.