# 776 Bush St

Block 0273, lot 008. Page: https://www.permitgraph.org/a/0273/008

- City's use: Multi-Family Residential
- Built: 1911
- Stories: 6
- Units: 61
- Rooms: 60 bathrooms
- Building: 45,515 sq ft
- Lot: 9,912 sq ft
- Zoning: RC4
- Construction type: C

From the assessor's latest secured roll, which can lag recent work.

## Permits filed here

13 permits filed for this property since 2000.

| Permit | Filed | Outcome | Address | Contractor | Work described on the permit | Declared cost |
| --- | --- | --- | --- | --- | --- | --- |
| [202511250372](https://www.permitgraph.org/p/202511250372) | Nov 25, 2025 | Completed: final sign-off Aug 2026 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Diablo Telecom & Construction Inc](https://www.permitgraph.org/contractor/diablo-telecom-construction-inc-1097926) | at&t modification of an (e) unmanned wireless facility consisting of r/r 3 antennas; r/r 1 power plant with netsure 7100 pp; install 1 battery rack; relocate 12 existing 190 amp (8) 180a batteries to… | $50,200 |
| [202405232784](https://www.permitgraph.org/p/202405232784) | May 23, 2024 | In progress: issued Sep 2024 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [C & E Electric & Fire Alarm Services](https://www.permitgraph.org/contractor/c-e-electric-fire-alarm-services-895194) | fire alarm replacement and install new lf horns to comply with sffc 1103.7.6.1 | $61,200 |
| [202212027538](https://www.permitgraph.org/p/202212027538) | Dec 2, 2022 | Never finaled: filed Dec 2022, never issued | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [B B J Electric, Inc](https://www.permitgraph.org/contractor/b-b-j-electric-inc-670906) | install new f/a system for elevator control functions only. building does not have f/a system | $8,425 |
| [202203149888](https://www.permitgraph.org/p/202203149888) | Mar 14, 2022 | Completed: final sign-off Sep 2022 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Ericsson Inc Dba E U S Inc](https://www.permitgraph.org/contractor/ericsson-inc-dba-e-u-s-inc-698896) | at&t: remove + replace 8 panel antennas. install 1 dc 9 box on panthouse, 1 #6 awg dc power trunk. 1 new fiber trunk to new dc9. new rf safety signs + burriers / stripping. remove 24 batteries. insta… | $45,000 |
| [202009093768](https://www.permitgraph.org/p/202009093768) | Sep 9, 2020 | Completed: final sign-off Apr 2021 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Ericsson Inc Dba E U S Inc](https://www.permitgraph.org/contractor/ericsson-inc-dba-e-u-s-inc-698896) | at&t proposes to modify and existing facility as follows:· remove and replace 3 existing antennas· remove 3 existing rru's· install 6 new rru's· all other related equipment being placed in existing c… | $21,000 |
| [201810163310](https://www.permitgraph.org/p/201810163310) | Oct 16, 2018 | Completed: final sign-off May 2019 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Shah & Associates Inc Dba P D C Corporat](https://www.permitgraph.org/contractor/shah-associates-inc-dba-p-d-c-corporat-920446) | att modification. remove and replace 3 extg antennas with 3 new antennas; install 3 new rrus and other small equip, remove unused equip. no change to batteries. n/a for maher. | $21,000 |
| [201712065666](https://www.permitgraph.org/p/201712065666) | Dec 6, 2017 | Expired or cancelled: withdrawn Jun 2018 | [776 Bush St](https://www.permitgraph.org/a/0273/008) |  | swap (3) rrus, swap (2) panel antennas, install (1) 5216 and (1) xmu unit inside existing indoor rack | $15,000 |
| [201605107049](https://www.permitgraph.org/p/201605107049) | May 10, 2016 | Completed: final sign-off Feb 2017 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Triton Tower Inc](https://www.permitgraph.org/contractor/triton-tower-inc-794622) | modification to an extg at&t facility consisting of r/r 6 extg antennas with 6 new antennas, extg dul unit with other misc equipment inside extg rack & 3 extg dc2 surge suppressors with 3 nw ones. in… | $29,000 |
| [201407252181](https://www.permitgraph.org/p/201407252181) | Jul 25, 2014 | Completed: final sign-off Dec 2014 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Triton Tower Inc](https://www.permitgraph.org/contractor/triton-tower-inc-794622) | modify (e) at&t facility including: raising all 12 (e) antennas by approx. 1.5 ft. remove / replace 3 (e) antennas. add 3 (n) rrus with a-2 units, add 3 (n) surge suppressors. add 1 (n) 4 inch condui… | $20,000 |
| [M368527](https://www.permitgraph.org/p/M368527) | Jan 28, 2013 | Never finaled: issued Jan 2013, no final | [776 Bush St](https://www.permitgraph.org/a/0273/008) |  | street space |  |
| [201011104706](https://www.permitgraph.org/p/201011104706) | Nov 10, 2010 | Completed: final sign-off Jul 2011 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Cba Site Services Inc.](https://www.permitgraph.org/contractor/cba-site-services-inc-455726) | a modification to an (e) unmanned telecommunications facility consisting of adding a (n)6601 rbs cabinet in an(e)19" rack,(n) inner ducts for fiber,(6)(n)rrv's,(3)(n) surge suppressors, a(n) splice b… | $32,000 |
| [201005112194](https://www.permitgraph.org/p/201005112194) | May 11, 2010 | Completed: final sign-off Sep 2010 | [776 Bush St](https://www.permitgraph.org/a/0273/008) | [Cba Site Services Inc.](https://www.permitgraph.org/contractor/cba-site-services-inc-455726) | a modification to an (e) telecommunications facility consisting of removing and replacing an (e) antenna w/a (n) antenna & installing (3) (n) btmas's, (3) ret's & (12) runs of 7/8" coax. also install… | $25,000 |
| [200812299262](https://www.permitgraph.org/p/200812299262) | Dec 29, 2008 | Expired or cancelled: cancelled Nov 2011 | [776 Bush St](https://www.permitgraph.org/a/0273/008) |  | at & t wireless proposes to modify an existing telecommunications facility, install 6 additional coax lines, no water or sewer is required, as the facility is unmanned, swap location of antennas in t… | $5,000 |

## Who worked here

Everyone with a license on these permits, by role, with how many permits each is on.

- Contractors: [Cba Site Services Inc.](https://www.permitgraph.org/contractor/cba-site-services-inc-455726) (2), [Ericsson Inc Dba E U S Inc](https://www.permitgraph.org/contractor/ericsson-inc-dba-e-u-s-inc-698896) (2), [Triton Tower Inc](https://www.permitgraph.org/contractor/triton-tower-inc-794622) (2), [B B J Electric, Inc](https://www.permitgraph.org/contractor/b-b-j-electric-inc-670906), [C & E Electric & Fire Alarm Services](https://www.permitgraph.org/contractor/c-e-electric-fire-alarm-services-895194), [Diablo Telecom & Construction Inc](https://www.permitgraph.org/contractor/diablo-telecom-construction-inc-1097926), [Shah & Associates Inc Dba P D C Corporat](https://www.permitgraph.org/contractor/shah-associates-inc-dba-p-d-c-corporat-920446)
- Architects: [Bradky Williams](https://www.permitgraph.org/professional/bradky-williams-C38310)
- Engineers: [Adam Amortnont](https://www.permitgraph.org/professional/adam-amortnont-81495), [Chris Lee](https://www.permitgraph.org/professional/chris-lee-76549), [Jose Carlos Faz](https://www.permitgraph.org/professional/jose-carlos-faz-S6550), [Streamline](https://www.permitgraph.org/professional/streamline-S6336)
- Authorized agents: [Jonathan Carreto](https://www.permitgraph.org/professional/jonathan-carreto-670906)
- Designers: [Chris Lee](https://www.permitgraph.org/professional/chris-lee-76549), [James Spore](https://www.permitgraph.org/professional/james-spore-70937)

---
Source: City and County of San Francisco building permit records (DataSF, https://data.sf.gov/), permits filed since 1 January 2000, reloaded nightly. Data as of 22 November 2026.
This is the text of https://www.permitgraph.org/a/0273/008.